7.10.5 Pressure and Flow Command Limit

Code
Name
Protection
function
F4.00
word
Minimum pressure command
F4.21
limit
Maximum pressure command
F4.22
limit
F4.23 Minimum flow command limit
F4.24 Maximum flow command limit
Tab. 7-23: Parameter list of pressure and flow command limit
The minimum pressure and flow command limitation (F4.21 and F4.23) works all
the time, independently to any control bit. That means if the setting pressure or
flow command is lower than [F4.21] or [F4.23], it will be limited to [F4.21] or
[F4.23] without any error / warning message.
The maximum pressure and flow command limitation can be activated via bit2 of
F4.00. This function will check whether the pressure or flow command given by
customer exceeds the limitation set in [F4.22] and [F4.24]. If a given command
exceeds its limitation, the effective command value will be limited to the maxi-
mum limit, and a warning signal will be raised.
DOK-RCON03-FCP5020****-QU02-EN-P
Setting range
0...15
Bit0: Pressure sensor failure
(PSF)
control
Bit1: Actual pressure monitor-
ing
Bit2: p/Q max. command limit
Bit3: Oil changing detection
0.0...[F4.22] bar
[F4.21]...1,000.0 bar
0...[F4.24] rpm
[F4.23]...5,000 rpm
Bosch Rexroth AG
Block Diagram of Main Functions
Default
0
5.0
250.0
200
3,000
Min.
Attri.
-
Run
0.1
Stop
0.1
Stop
1
Stop
1
Stop
47/75