Installation
Fig. 42 Transport, lifting and handling
Preparing the appliance installation
NOTICE:
Incorrect mounting can cause material damage.
If the appliance is mounted incorrectly, it may fall off the wall.
▶ Only install the appliance on a rigid, solid wall. This wall must be able
to carry the weight of the appliance and must at least be as large as
the bearing surface of the appliance.
▶ Only use screws and wall plugs that are suitable for the wall type and
weight of the appliance.
To make it easier to install the pipework, we recommend using a
mounting plate. More information about this accessory can be found in
our main catalogue.
▶ Remove the packaging, observing all notices in the packaging.
▶ Make sure that the gas type specified on the data plate is the same as
the gas type supplied.
▶ Make sure that the installation location is in the country of destination
specified on the data plate.
▶ Affix an installation template (if available) to the wall.
▶ Check whether the screws and wall plugs supplied with the appliance
can be used.
▶ Remove installation template from wall.
▶ Drill suitable holes for the selected wall plugs and screws.
▶ Fasten the mounting bracket to the wall using 4 screws and wall plugs
(scope of delivery).
▶ Attach the mounting plate to the lower screws and tighten.
32
1
2
0010023273-001
Fig. 43 Fitting the mounting bracket and the mounting plate
5.2

Appliance connections

WARNING:
Appliance gas connection
▶ Ensure the mains gas supply is isolated before starting any work
and follow all relevant safety precautions.
NOTICE:
Appliance hydraulic connections
▶ Ensure all water pipe work, to be connected, is isolated/drained and
observe all relevant safety precautions.
▶ Be aware of plastic components when using a naked flame on pipe
work.
Surplus water may be present inside the appliance due to factory testing.
External condensate pipe work or internal pipe runs in unheated areas
such as lofts, basements and garages exposed to prolonged cold
temperatures should be protected  chapter 4.5.
NOTICE:
Commissioning without water damages the appliance!
▶ Operate this appliance only when filled with water
Greenstar 8000 Style – 6720883855 (2019/01)