Fan Removal; Cleaning The Heat Exchanger - Bosch Worcester Greenstar 8000 Series Installation And Maintenance Instructions Manual

Gas fired condensing system boiler
Table of Contents

Advertisement

8.9.3

Fan removal

1. Undo connection of venturi.
2. Remove venturi and move pipe to the far right.
2.
Fig. 80 Venturi removal
3. Remove expansion foam (pull towards you).
4. Undo fan connection and remove screw and seal.
5. Remove fan.
4.
3.
Fig. 81 Fan removal
Greenstar 8000 Style – 6720883855 (2019/01)
1.
0010023759-001
5.
0010023760-001
8.9.4

Cleaning the heat exchanger

Access to the heat exchanger
The following items will have to be removed to gain access to the heat
exchanger for cleaning:
▶ Remove the combustion casing.
▶ Lower the control panel into the service position.
▶ Disconnect electrical wires to the fan, ignition transformer, spark
electrodes, flue overheat thermostat, main heat exchanger
temperature sensor and flow pipe temperature sensor.
▶ Flueway
▶ Fan assembly
▶ Ignition transformer
▶ Spark electrode assembly
▶ Burner housing, burner and gasket
Cleaning the heat exchanger
▶ Remove the siphon and place a suitable container under the outlet to
catch the water and debris.
▶ Protect the controller from water ingress.
The heat exchanger does not have to be removed in order to clean.
The heat exchanger is shown removed from the appliance to illustrate
cleaning more clearly.
▶ Remove the cleaning access cover [1] and seal [2].
2
Fig. 82 Access cover removal
Inspection and maintenance
1
0010023710-001
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Worcester gr8700iw 30 s ngWorcester gr8700iw 35 sb ngWorcester gr8700iw 30 s lpgWorcester gr8700iw 35 s lpgWorcester gr8700iw 30 sb lpgWorcester gr8700iw 35 sb lpg ... Show all

Table of Contents