Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual page 11

Hand-held terminal
Table of Contents

Advertisement

DOK-SUPPL*-VEH*30.2***-PR03-EN-P
Rexroth IndraControl VEH 30.2 Hand-Held Terminal
the connection. Connecting cables with a production date before 2011 with
an angled plug, are fitted in a 45° angle to the horizontal. Only if the connec‐
tor snaps in properly, the correct position is reached. Now turn the knurled
nut with slight pressure on the flange.
NOTICE
While the connector is screwed on a VAC 30.2 connection module, a relay
activates the stop button. In this way the IndraControl VEH 30.2 is supplied
with voltage. Screw the knurled nut as far as the rubber seal is completely
covered and the end position is reached to ensure the optimal connection of
the contacts and to achieve the specified degree of protection.
Verify all three positions of the enabling button from both sides for correct
function during commissioning of the IndraControl VEH 30.2 and regularly
during routine operation.
Verify the stop pushbutton for correct function in safe state of the plant of the
IndraControl VEH 30.2 in regular intervals and during commissioning.
The device may only be commissioned and connected by qualified staff.
Find further details about commissioning in the documentation of the device
or installation manufacturer.
Bosch Rexroth AG
System Presentation
Loss of specified degree of protection due to
incorrect connection of contacts.