Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual page 81

Hand-held terminal
Table of Contents

Advertisement

DOK-SUPPL*-VEH*30.2***-PR03-EN-P
Rexroth IndraControl VEH 30.2 Hand-Held Terminal
WARNING
The enabling enabling device is only suitable as safety function if the
person activating the enabling button recognizes the dangerous situa‐
tion in time so that he or she can immediately take the necessary meas‐
ures to avoid such situations.
As additional measure reduced speed of the movement can be neces‐
sary. The allowed speed must be determined by means of a risk as‐
sessment.
The enabling device must not be used as only component for initiating
dangerous states. For initiating dangerous states a second, intentional
start command is necessary (button on the hand-held terminal).
Only the person who operates the enabling device is allowed to work in
the dangerous area.
For further information regarding the enabling device, do observe also
chapter 4.4 "Enabling Device" on page 26
abling Button" on page
Bosch Rexroth AG
Pin Assignments of the IndraControl VEH 30.2
Non-functioning enabling devices can have
lethal consequences!
and
chapter 7.1.6 "X2.2: En‐
69.