Bosch REXROTH IndraControl VEH 30.2 Project Planning Manual page 84

Hand-held terminal
Table of Contents

Advertisement

82/109
Bosch Rexroth AG
Maintenance and Installation
Type of mal‐
Operating
function
device
Enabling is not
OK
possible
Enabling only
OK
possible on the
left side.
Enabling only
OK
possible on the
right side
Connector can‐
-
not be plugged
in
Tab.8-1:
Error table
DOK-SUPPL*-VEH*30.2***-PR03-EN-P
Rexroth IndraControl VEH 30.2 Hand-Held Terminal
Enabling
Enabling
Possible cause Measure
device,
button,
left side
right side
No reac‐
No reac‐
Button me‐
tion
tion
chanically
damaged.
Cable dam‐
aged.
OK
Defective XOR operation,
the pushbutton
gets stuck.
Internal me‐
chanics dam‐
aged.
Defective OK
XOR operation,
the pushbutton
gets stuck.
Internal me‐
chanics dam‐
aged.
-
-
Wrong connec‐
tor orientation.
Wrong cable
coupling.
Plug-pins dam‐
aged.
Use a new de‐
vice.
Use a new ca‐
ble or a new
device.
Relieve the left
button, retry.
Otherwise, use
a new device.
Relieve the
right button, re‐
try.
Otherwise, use
a new device.
Turn correctly.
Use an ade‐
quate cable.
Replace de‐
vice/cable.

Advertisement