Download Print this page

Siemens SINAMICS G130 Operating Instructions Manual page 36

Dv/dt filter compact plus voltage peak limiter
Hide thumbs Also See for SINAMICS G130:

Advertisement

Technical specifications
Table 6- 4
Technical data for the dv/dt filter compact plus Voltage Peak Limiter, 3 AC 500 V ... 600 V, part 1
Article number
Suitable for Power Module
Unit rating of the Power
Module
I
thmax
Degree of protection
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Terminals
- 1U1/1V1/1W1
- DCPS/DCNS
- 1U2/1V2/1W2
- PE
Max. permissible cable
length between dV/dt filter
and motor
Dimensions
Width
Height
Depth
Weight, approx.
34
6SL3000-
2DG32-2EA0
6SL3310-
1GF31-8AA3
1GF32-2AA3
kW
110
132
A
215
IP00
kW
0.305
kW
0.316
kW
0.372
for M10 bolt
for M8 screw
for M10 bolt
M6 screw
m
mm
350
mm
317
mm
260
kg
51
2DG33-3EA0
1GF32-6AA3
1GF33-3AA3
160
200
330
IP00
0.385
0.399
0.480
for M10 bolt
for M8 screw
for M10 bolt
M6 screw
100 (shielded)
150 (unshielded)
350
317
260
60
dV/dt filter compact plus Voltage Peak Limiter
Operating Instructions, 11/2017, A5E02590131A
2DG34-1EA0
1GF34-1AA3
250
410
IP00
0.550
0.568
0.678
for M12 bolt
for M8 bolt
for M12 bolt
M6 screw
440
369
311
87

Advertisement

loading