6.18 AT^SMSO Switch off mobile station

Test command
Response
OK
AT^SMSO=?
Response
Execute command
^SMSO: MS OFF OK
AT^SMSO
Device will be switched off (power down mode)
Note
Reference
Do not send any command after this command
Siemens

6.19 AT^SM20 Set M20 Compatibility

Test command
Response
OK
AT^SM20=?
Read command
Response
^SM20: <n>
AT^SM20?
OK
Parameters
See write command
Write command
Response
AT^SM20=<n>
Response
M20 is an earlier, widely used SIEMENS GSM engine. The AT^M20 command
simply controls the behaviour of the ATD command during voice calls. Please
note that this command has no effect on any other differences between M20
and products based on x35/37 firmware.
OK
Parameters
<n>
Reference
Note
Siemens
TC3X_ATC_01_V04.00
0
Compatible to x35/37mobiles.
If this mode is active, TA returns OK right after attempting a
call.
1
Compatible to M20.
If the M20 mode is active, TA returns OK once the call is
successfully set up. Issuing any command before TA returns
OK will cancel the call setup.