At&W Store Current Configuration To User Defined Profile - Siemens TC37 Module At Command Reference

At command set cellular engines
Table of Contents

Advertisement

AT Command Set
2.39 AT&W Store current configuration to user defined profile
Execute command
TA stores the current settings to a user defined profile in the non-volatile memory.
AT&W[<n>]
Response
OK or if error is related to ME functionality: ERROR / +CME ERROR: <err>
Parameter
<n>
Reference
Note
V.25ter
The user defined profile will be loaded automatically after PowerUp. Use ATZ to
restore user profile and AT&F to restore factory settings. Until the first use of
AT&W, ATZ works as AT&F. See Chapter 2.33 for details on ATZ and Chapter
2.36 for AT&F.
List of settings stored to user defined profile:
· ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS.
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10,
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR.
User defined profiles in multiplex mode:
· On each multiplexer channel you can save an individual profile.
· List of settings stored to profile on multiplexer channel 1:
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS.
AT&C, AT&D, AT&S, ATS0, ATS3, ATS4, ATS5, ATS6, ATS7, ATS8, ATS10,
ATS18, AT+FCLASS, AT+CBST, AT+CRLP, AT+CR.
· List of settings stored to profile on multiplexer channels 2 and 3:
ATE, ATQ, ATV, ATX, AT+CRC, AT+CMGF, AT+CSDH, AT+CNMI, AT+ILRR,
AT+CMEE, AT^SMGO, AT+CSMS, AT^SACM, ^SCKS, AT+CREG, AT+CLIP,
AT+COPS. (Parameters for data call are not relevant on channels 2 and 3.)
TC3X_ATC_01_V04.00
0 number of profile
Page 37 of 204
29.05.2002

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc35 moduleTc35 terminal