Transport And Storage Conditions - Siemens SIMATIC HMI Operating Instructions Manual

Industrial usb hub 4
Hide thumbs Also See for SIMATIC HMI:
Table of Contents

Advertisement

Available languages

Available languages

Emission of Radio Interference
Emission from electromagnetic fields according to 55011, limit value Class A, Group 1,
measured at a distance of 10 m:
30 to 230 MHz
230 to 1000 MHz
Additional measures
Before connecting a device to the public power network, ensure that it is compliant to limit
class B according to EN 55022.
2.5

Transport and storage conditions

Mechanical and climatic transport and storage conditions
The requirements regarding transport and storage conditions for the device are more
stringent than those laid down in IEC 61131-2. The following requirements apply to the
transport and storage of the device in its original packing.
The climatic conditions correspond to the requirements of the following standards:
● IEC 60721-3-3, Class 3K7 for storage
● IEC 60721-3-2, Class 2K4 for transport
The mechanical conditions correspond to IEC 60721-3-2, Class 2M2.
Type of condition
Drop test (in transport package)
Temperature
Atmospheric pressure
Relative humidity
Sinusoidal vibration according to
IEC 60068-2-6
Impact according to IEC 60068-2-29
NOTICE
Ensure that no condensation (dew) develops on or inside the device after transporting it at
low temperatures or after it has been exposed to extreme temperature fluctuations.
The device must have acquired room temperature before it is put into operation. Do not
expose it to direct heat radiation from a heating device. If dew has developed, wait
approximately four hours until the device has dried completely before switching it on.
Proper transport and storage, installation and assembly as well as careful operation and
maintenance are prerequisites for trouble-free and safe operation of the device.
Non-compliance shall result in the voiding of the device warranty.
Industrial USB Hub 4
Operating Instructions, 09/2007, A5E00471973-02
< 40 dB (V/m) quasi-peak
< 47 dB (V/m) quasi-peak
Permitted range
≤ 1 m
–20 to +60 °C
1080 to 660 hPa,
corresponds to an elevation of -1000 to 3500 m
10 to 90 %, without condensation
5 Hz to 9 Hz: 3.5 mm
9 to 500 Hz: 9.8 m/s
250 m/s
2
Safety Instructions and General Notes
2.5 Transport and storage conditions
2
, 6 ms, 1,000 impacts
77