Power Section (Hms01.1N-W0150 - Bosch Rexroth IndraDrive M Project Planning Manual

Drive controllers, power sections
Hide thumbs Also See for Rexroth IndraDrive M:
Table of Contents

Advertisement

7-8
Electrical Installation

Power Section (HMS01.1N-W0150...0210)

Designation
DC bus voltage(range)
Upper DC bus voltage
limit (cut-off threshold)
Output voltage
Fundamental voltage
Continuous output
current (effective
value)
or rated current
Maximum output current
(effective value at
operation at overload)
Base load current
available at maximum
current (effective value)
Characteristic curve
output current
Peak load allowance
factor / duration
– at f
= 4 kHz
s
– at f
= 8 kHz
s
– at f
= 10 kHz
s
– at f
= 12 kHz
s
– at f
= 16 kHz
s
Symbol
U
DC
U
DC limit (max)
U
out
eff
U
= 475 V
DC
U
= 750 V
DC
I
out_eff
cont2 (4 kHz)
I
out_eff
cont2 (8 kHz)
I
out_eff
cont2 (10 kHz)
I
out_eff
cont2 (12 kHz)
I
out_eff
cont2 (16 kHz)
I
out_eff
max (4 kHz,400 ms)
I
out_eff
max (8 kHz,400 ms)
I
out_eff
max (10 kHz,400 ms)
I
out_eff
max (12 kHz,400 ms)
I
out_eff
max (16 kHz,400 ms)
I
I
out_eff
cont1 (4 kHz,
out_eff
max)
I
I
out_eff
cont1 (8 kHz,
out_eff
max)
I
I
out_eff
cont1 (10 kHz,
out_eff
max)
I
I
out_eff
cont1 (12 kHz,
out_eff
max)
I
I
out_eff
cont1 (16 kHz,
out_eff
max)
-
I
/ I
out_max
out_cont1 (4 kHz)
I
/ I
out_max
out_cont1 (8 kHz)
I
/ I
out_max
out_cont1 (10 kHz)
I
/ I
out_max
out_cont1 (12 kHz)
I
/ I
out_max
out_cont1 (16 kHz)
Unit
HMS01.1N-W0150
V
254...750
900 ± 2.5%
V
V
0...336
0...530
A
100
67
57
48
37
A
150
104
88
75
57
A
65
45
37
32
24
-
I
I
out_eff max
I
out eff cont2
400 ms
time for one cycle 3.6 s
A
2,3
2,3
2,4
2,3
2,4
Rexroth IndraDrive M
HMD01.1N-W0210
254...750
900 ± 2.5%
0...336
0...530
150
101
85
72
54
210
144
121
103
77
105
72
60
51
39
I
out_eff_cont1
2
2
2
2
2
DOK-INDRV*-HMS+HMD****-PR01-EN-P
t

Hide quick links:

Advertisement

Table of Contents
loading