7-10
Electrical Installation

Control Voltage

Designation
Control voltage
Max. ripple content
Max. allowed overvoltage
Max. charging current
Max. pulse duration of I
EIN3
Max. input capacity
Power consumption*:
HMD01.1-1N-W0012
HMS01.1-1N-W0020
HMD01.1-1N-W0020
HMS01.1-1N-W0036
HMD01.1-1N-W0036
HMS01.1-1N-W0054
HMS01.1-1N-W0070
HMS01.1-1N-W0150
HMS01.1-1N-W0210
(Information at ambient temperature of 25 °C)
Symbol
Unit
U
V
N3
w
-
U
V
N3max
I
A
EIN3
t
ms
EIN3Lade
C
mF
N3
P
W
N3
P
W
N3
P
W
N3
P
W
N3
P
W
N3
P
W
N3
P
W
N3
P
W
N3
P
W
N3
* data without motor holding brake taken into account
Fig. 7-4:
Control voltage
Rexroth IndraDrive M
Value
24 ±20%
(when no motor holding brake is used)
24 ±5%
(when motor holding brake is used)
26 ±5%
(when motor holding brake is used and the
motor cable is longer than 50 m)
mustn't exceed the control voltage range
33 (limited to a duration of 1 ms)
2.5 (power section)
2.8 (control section)
5
0.47
being prepared
10.1 (0.42 A at 24 V)
being prepared
15.1 (0.63 A at 24 V)
being prepared
9.6 (0.40 A at 24 V)
16.1 (0.67 A at 24 V)
22.8 (0.95 A at 24 V)
72.0 (3.00 A at 24 V)
DOK-INDRV*-HMS+HMD****-PR01-EN-P