Hardware Configuration Of Pcu 50.5; Network Settings; Partitioning Of The Ssd - Siemens SINUMERIK 840DE sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Delivery condition

1.2 Hardware configuration of PCU 50.5

1.2
Hardware configuration of PCU 50.5
1.2.1

Network settings

The PCU 50.5 has two Ethernet interfaces with default settings suitable for connection to
SINUMERIK solution line:
Figure 1-1
Hardware
designations
X1
X2
The network designation may deviate depending on the system.
1
Further information
Manual SINUMERIK 840D sl Operator Components and Networking
● Setting the IP address and domain (Page 32)
● Adapting the firewall settings (Page 67)
● Remote access (Page 165)
● Network settings in the Service Center (Page 125)
1.2.2

Partitioning of the SSD

The PCU 50.5 has a SSD with 80 GB storage capacity. The SSD is already partitioned and
pre-assigned by the PCU base software as follows:
Name
File system
10
Ethernet interfaces of the PCU
Designation in
PCU Base Software
1
Local Area Connection 2 Preset as a DHCP client for connection to a company net‐
Local Area Connection
System (C:)
NTFS
Configuration
work.
The IP address is dynamically fetched from the DHCP server
at X1.
Preset as a SINUMERIK DHCP server for connection to a
system network.
A fixed IP address is preset at X2: If 192.168.214.241 is free
in the system network, it is set.
Otherwise you can view the allocated fixed IP address in the
Control Panel.
Data (D:)
NTFS
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
PCU Base Software (IM10)