Hardware Configuration Of Simatic Ipc; Network Settings; Partitioning Of The Ssd - Siemens SINUMERIK 840DE sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Delivery condition

1.3 Hardware configuration of SIMATIC IPC

1.3
Hardware configuration of SIMATIC IPC
1.3.1

Network settings

The supported SIMATIC IPC have two Ethernet interfaces which are set by the PCU Base
Software for connection to the SINUMERIK solution line.
Table 1-1
Hardware
designations
X1
X2
The network designation may deviate depending on the system.
1
Further information
● Operating instructions of the SIMATIC IPC
● Setting the IP address and domain (Page 32)
● Adapting the firewall settings (Page 67)
● Remote access (Page 165)
● Network settings in the Service Center (Page 125)
1.3.2

Partitioning of the SSD

The partitioning of the SSD of your SIMATIC IPC627D or IPC427D is not changed by the
installation of the PCU-Basesoftware. Partition C: must have a minimum size of 30 GB to be
able to install the PCU-Basesoftware.
Name of the partition
File system
Memory used by the system
12
SIMATIC
Designation in
PCU Base Software
1
Local Area Connection 2 Preset as a DHCP client for connection to a company net‐
Local Area Connection
System (C:)
NTFS
~ 20 GB
Configuration
work.
The IP address is dynamically fetched from the DHCP server
at X1.
Preset as a SINUMERIK DHCP server for connection to a
system network.
A fixed IP address is preset at X2: If 192.168.214.241 is free
in the system network, it is set.
Otherwise you can view the allocated fixed IP address in the
Control Panel.
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
Data (D:)
NTFS
~ 0 GB
PCU Base Software (IM10)