Configuration of the system

4.6 Configuring network access on the USB data storage medium

4.6
Configuring network access on the USB data storage medium
If you connect a removable data storage medium (e.g. a USB flash drive) to a USB interface
of the PC system, a network drive is set up automatically. In this way, a removable data storage
medium can be accessed from an NCU in the network. The file and the printer release is
activated automatically by Windows.
If you do not require network access to USB removable data storage medium, you should
deactivate the automatic network release.
You can find this setting in the basesys.ini at EnableUSBShares.
Requirement
● Hidden directories are not hidden
● A copy of the basesys.ini configuration file is stored in the user directory: C:
\ProgramData\Siemens\MotionControl\user\System\etc\basesys.ini
● The basesys.ini configuration file in the user directory is not write-protected
See: Directory structure and file conventions (Page 14)
Procedure
To configure the automatic network release of USB data storage media of the PC system,
proceed as follows:
1. Open the basesys.ini configuration file in the C:\ProgramData\Siemens
\MotionControl\user\System\etc\ directory.
2. Remove the semicolon in front of the EnableUSBShares line and set the required value.
– EnableUSBShares=0
– EnableUSBShares=1 (default value)
3. Save and close the file.
34
The automatic network release of USB data storage media (and the associated file and
printer release) is deactivated.
The automatic network release of USB data storage media is activated.