Assigning Functions To Cross-Point Buttons Of The Cross-Point Control Block - Sony XVS-9000 User Manual

Multi format switcher system
Hide thumbs Also See for XVS-9000:
Table of Contents

Advertisement

3
Enter a name of up to 8 characters in the keyboard
window, and press [Enter].
Setting the transition rate target to display
on memory recall buttons
This sets the memory recall button assignments in
transition rate display mode.
1
In the Engineering Setup >Panel >Prefs/Utility
>Utility Module Assign menu (7324.1), press [Trans
Rate Mode Assign].
The Trans Rate Mode Assign menu (7324.3) appears.
2
Select the target button to set.
3
Select the transition rate to assign.
4
Press [Set].
To release the assignment
Select the target button to release, then press [Clear].
Assigning Functions to Cross-Point
Buttons of the Cross-Point Control
Block
You can assign functions to the cross-point buttons of the
cross-point control block (utility/shotbox mode).
1
In the Engineering Setup >Panel >Prefs/Utility menu
(7324), press [Xpt Module Assign].
The Xpt Module Assign menu (7324.2) appears.
2
Select the target button to set.
No.
Parameter Adjustment
1
Bank
Bank selection
2
Button No
Button selection
3
In the <Action> group, select the function to assign.
Menu Shortcut: Assign a frequently used menu to be
recalled (menu shortcut).
Utility Command: Assign a function setting (utility
command).
Macro Recall: Assign a macro register recall.
Shotbox Recall: Assign a shotbox register recall.
4
Perform the following operations, according to the
selection in step 3.
When [Menu Shortcut] is selected: When a cross-
point button on the cross-point control block is
blinking, display the shortcut menu. Press the
target button to set to assign a shortcut. When
finished, press [Menu Shortcut] again.
When [Utility Command] is selected: Select a
command to assign in the list on the right side of
the status area.
No.
Parameter Adjustment
3
Command
a)
4
GPI No
a) DCU GPI Test Fire command only
When [Macro Recall] is selected: Select the macro
register to assign.
No.
Parameter Adjustment
3
Macro
When [Shotbox Recall] is selected: Select the
shotbox register to assign.
No.
Parameter Adjustment
3
Shotbox
5
Press [Action Set].
When [Menu Shortcut] is selected in step 3, it is not
necessary to press [Action Set].
To release the assignment
Select the target button to release, then press [Clear].
To display register names in the Utility Command
field
When [Macro Recall] or [Shotbox Recall] is selected in
step 3, you can select whether to display register names in
the Utility Command field.
To enable display, press [Reg Name Display], turning it
on.
For details about utility commands that can be assigned to
cross-point buttons, see "List of utility commands and user
preference button states" (page 413).
Settings names to show on the display
You can set the names to display when menu shortcuts or
utility commands are assigned to cross-point buttons.
Note
When a macro register is assigned, the names specified in
the Macro menu are displayed on the display. When a
shotbox register is assigned, the names specified in the
Shotbox menu are displayed on the display.
1
In the Engineering Setup >Panel >Prefs/Utility >Xpt
Module Assign menu (7324.2), select the target button
to set.
418
Utility command selection
GPI number
Macro register selection
Shotbox register selection

Hide quick links: