Parameters/address space
4.3 Declaration of parameters
The following figure shows the number of module cycles after which the smoothed analog
value is almost 100%, depending on the set smoothing. It is valid for each signal change at
the analog input.
Figure 4-3
Hardware interrupt 1 or 2
Enabling of a hardware interrupt at violation of high limit 1 or 2 or low limit 1 or 2.
Low limit 1 or 2
Specifies the low limit threshold that triggers hardware interrupt 1 or 2.
High limit 1 or 2
Specifies the high limit threshold that triggers hardware interrupt 1 or 2.
24
None (k = 1)
Weak (k = 4)
Medium (k = 16)
Strong (k = 32)
Smoothing for AI 8xU/I/R/RTD BA
Analog Input Module AI 8xU/I/R/RTD BA (6ES7531-7QF00-0AB0)