HP 12500 Series Installation Manual page 18

Routing switch
Table of Contents

Advertisement

LED
Fault
Table 5 AC power supply specifications
Item
Rated input voltage range
Max input voltage range
Max input current
Max output power
Power monitor module
The power monitor module (callout 7 in
operating status of the power supplies in real time. It is located between the power supply slot area and
the power switch.
PEM
The PEM (see
Figure 12 PEM location
 
Table 6 PEM description
PEM
LSTM2PEMC6 (PEM-C20)
Status
Off
Steady on
Off
Description
100 VAC to 120 VAC/200 VAC to 240 VAC @ 50 Hz or 60 Hz
90 VAC to 264 VAC @ 47 Hz to 63 Hz
13.3 A
2000 W at 200 VAC to 240 VAC input
1200 W at 100 VAC to 120 VAC input
Figure
12) provides power to the power supplies.
Description
Applied to the 110 V or 220 V
single-phase three-wire AC power
supply system.
One PEM provides six standalone
C20 (16A) sockets numbered in
two rows: 1, 3, and 5 in the top
row, and 2, 4, and 6 in the bottom
row, from left to right.
Description
The AC power supply is operating properly.
The AC power supply is faulty.
The AC power supply is operating properly.
Figure
10) monitors the alarm status, in-position status, and
Max number of power supplies
6 (each C20 socket for one power supply)
12