Configuring Temperature Thresholds For A Card - HP 12500 Series Installation Manual

Routing switch
Table of Contents

Advertisement

Line-card power status:
Slot
----
2
3
4
5
6
7
8
9

Configuring temperature thresholds for a card

You can set temperature thresholds for a card. When the temperature reaches the threshold, the switch
generates alarms.
Configuring temperature thresholds for a card
Step
1.
Enter system view.
2.
Configure temperature alarm
thresholds for a card.
Displaying the temperature information on your switch
Use the display environment command to display the temperature information of the sensors on the cards,
including the current temperature and temperature thresholds.
# Display the temperature information of the cards on the switch.
<Sysname> display environment
In standalone mode:
System temperature information (degree centigrade):
-------------------------------------------------------------------------------
Slot
1
1
1
5
5
5
Board-Type
Watts
---------------
-----
None
--
None
--
None
--
LST1GT48LEC1
190
None
--
None
--
None
--
None
--
Sensor
Temperature
inflow
1
21
outflow 1
24
hotspot 1
27
inflow
1
27
outflow 1
27
hotspot 1
30
Status
------
Absent
Absent
Absent
On
Absent
Absent
Absent
Absent
Command
system-view
In standalone mode:
temperature-limit slot slot-number { inflow | hotspot | outflow }
sensor-num lowerlimit warninglimit [ alarmlimit ]
In IRF mode:
temperature-limit chassis chassis-number slot slot-number { inflow |
hotspot | outflow } sensor-num lowerlimit warninglimit [ alarmlimit ]
LowerLimit
WarningLimit
-25
-15
-15
-20
0
-10
67
AlarmLimit ShutdownLimit
70
80
70
85
75
85
65
85
70
85
70
80
N/A
N/A
N/A
N/A
N/A
N/A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

125081250412518

Table of Contents