7. trOuBleShOOtiNG

Symptom
Unit does not operate
dehumidified volume
is small
Humidity remains too
high.
Weee reGulAtiONS
dispose of this product at the end of its working life in compliance with the eU directive on Waste electrical and electronic equipment
(Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.

eNVirONmeNt PrOteCtiON

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St edmunds, Suffolk. iP32 7Ar
01284 757500
© Jack Sealey limited
Potential cause
Is power supply connected?
Check to see if the water tank is full of water
i.e. is water level warning light on See 4.5.1.1.
Check to see if the water tank is fitted properly
in position.
Is filter dirty / clogged ?
Check for any obstructions to front and back
air inlets / outlets of unit.
low ambient temp.
low ambient humidity.
Room size may be too large.
doors and windows may be opened and
closed frequently.
The dehumidifier is used together with a
kerosene heater which emits water vapour.
01284 703534
Original Language Version
Possible remedy
Insert the plug into an electrical outlet fully and
securely - check fuse in plug is oK.
Remove front cover 4.5.1.2.
empty water out of the tank. See 4.5.1.4.
Remove front cover 4.5.1.2. and reposition
tank.
Clean filter section 5.1.
See section 1.2.
Unit does not work below approx 5
Unit has reached required level set.
Room size may exceed 12m
Keep doors and windows shut during
operation.
Turn heater off.
sales@sealey.co.uk
C.
o
.
3
www.sealey.co.uk
SdH102 Issue 1 07/11/18