Drive-Cliq Hub Module Dmc20; Dme20 Drive-Cliq Hub Module - Siemens NCU 7x0.3 PN Series Manual

Table of Contents

Advertisement

Connectable components

9.8 DRIVE-CLiQ Hub Module DMC20

9.8
DRIVE-CLiQ Hub Module DMC20
Properties
The DRIVE-CLiQ DMC20 Hub Module is used to implement point-to-point distribution of a
DRIVE-CLiQ line. With the DMC20, an axis grouping can be expanded with 4 DRIVE-CLiQ
sockets for additional subgroups.
The module is especially suitable for applications which require DRIVE-CLiQ nodes to be
removed in groups, without interrupting the DRIVE-CLiQ line and therefore the data
exchange.
CAUTION
The cooling clearances of 50 mm above and below the component must be observed.
Additional references
You can find further information on the DMC20 in the SINAMICS S120 manual titled "Control
Units and Additional System Components".
9.9

DME20 DRIVE-CLiQ Hub Module

Properties
The DME20 DRIVE-CLiQ Hub Module is used to implement point-to-point distribution of a
DRIVE-CLiQ line. With the DME20, an axis grouping can be expanded with 5 DRIVE-CLiQ
sockets for additional subgroups.
The component has degree of protection IP67 and is especially suitable for applications
which require DRIVE-CLiQ nodes to be removed in groups, without interrupting the DRIVE-
CLiQ line and therefore the data exchange.
The DME20 can be used with SINAMICS firmware version 2.6 or higher.
CAUTION
The cooling clearances of 50 mm above and below the component must be observed.
Additional references
You can find further information on the DME20 in the SINAMICS S120 manual titled "Control
Units and Additional System Components".
158
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0