Technical Data; Drive-Cliq Hub Module Dmc20; Description - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components

9.2 DRIVE-CLiQ Hub Module DMC20

9.1.9

Technical data

Table 9- 15
6SL3055-0AA00-3BA.
Current requirement X524 (at 24 V DC)
without DRIVE-CLiQ supply
Current requirement X514 (at 24 V DC)
without digital outputs and sensor power supply
Sensor power supply with and without forced dormant error detection (L1+, L2+, L3+)
Voltage
Max. load current per output
Max. cable length for the 24 V supply:
For longer cable lengths, surge protection device
"Weidmüller type No. MCZ OVP TAZ DIODE 24 VDC"
should be used.
Power loss
PE/ground connection
Weight
9.2
DRIVE-CLiQ Hub Module DMC20
9.2.1

Description

The DRIVE-CLiQ Hub Module DMC20 is a DRIVE-CLiQ component and can be snapped
onto a standard mounting rail (EN 60715). It is only used to connect direct measuring
systems for the feed axes and expansion axes of the S120 Combi.
Note
The DMC20 should also be used if only one feed axis is coupled with a direct measuring
system.
A fixed topology applies when assigning the particular feed axis to a DRIVE-CLiQ interface
(see Section Topology rules for DRIVE-CLiQ (Page 131)) and this must be observed.
222
Technical data
Unit
Value
mA
160
mA
38
V
24
A
0.5
m
30
W
4.5 at 24 V
At the housing with
M4 screw
kg
Approx. 0.9