X21/X22 Ep Terminals - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

S120 Combi Power Modules
4.3 Interface description
4.3.6

X21/X22 EP terminals

Table 4- 10
X21 EP terminals - infeed
Terminal
1
2
3
4
Table 4- 11
X22 EP terminal/temperature sensor - axes
Terminal
1
2
3
4
The temperature sensor type can be selected by parameter (see the SINAMICS S120/S150 List Manual).
1)
84
Designation
-
-
EP +24 V (Enable Pulses)
EP M1 (Enable Pulses)
Designation
+ Temp
- Temp
EP +24 V (Enable Pulses)
EP M1 (Enable Pulses)
Technical data
Reserved, do not use
Supply voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption, typical: 4 mA at 24 V
Isolated input
Type: Screw terminal 1 (Page 307)
Max. connectable cross-section: 1.5 mm
Tightening torque: 0.22 ... 0.25 Nm
Technical data
Temperature sensors
: KTY84–1C130 / PT1000 / PTC
1)
/ bimetallic switch with NC contact
Supply voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption, typical: 4 mA at 24 V
Isolated input
The pulse inhibit function is only available when Safety
Integrated Basic Functions are enabled.
Type: Screw terminal 1 (Page 307)
Max. connectable cross-section: 1.5 mm
Tightening torque: 0.22 ... 0.25 Nm
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
2
2
SINAMICS S120 Combi

Advertisement

Table of Contents
loading

Table of Contents