Controllers

5.4 Connecting terminals

5.4
Connecting terminals
5.4.1

Digital input signals

Slot X6
You can connect certain signals for drive functions at the inputs Input 1, Input 2, Input 3, Input 4
(X6) and Input 0 (X5). The following table shows how the drive function and input are assigned
depending on the control unit.
Table 5-2
Overview of signals for drive functions at slots X5 and X6
Slot X5/X6
Input 0
Input 1
Input 2
Input 3
Input 4
Input 1, Input 2, In‐
put 3 and Input 4 inac‐
tive
1)
Adjustable via the service menu "General setup > Special parameters > FBLOCK configuration > FBLOCK config. Standard
input"
Adjustable via the service menu "General setup > Special parameters > FBLOCK configuration > FBLOCK config. Emergency
2)
stop 3 inp."
Adjustable via the service menu "General setup > Special parameters > FBLOCK configuration > FBLOCK config. Cold storage
3)
mode"
4)
Note: Although the RC input is activated, it is always possible to move the door using the service buttons.
132
ATD401W
Standard input
Emergency stop with
1)
control concept Door
emergency stop via 3
NDG
(second force and ener‐
gy profile)
Parameterizable
(local sensor type)
Partial opening opera‐
tion
CLOSE DOOR
CLOSE DOOR (inverted)
OPEN DOOR
OPEN DOOR (inverted)
Deenergize (not a door
command)
ATD401W
three inputs
2)
(see Fail-safe digital
OPEN/CLOSE with
digital inputs
(Page 123))
Stop (inverted)
Parameterizable
(local sensor type)
Partial opening opera‐
Cord-operated switch
tion
(cord-operated switch
ATD401W
ATD420W / ATD430W
Cold storage func‐
tion
3)
RC
INPUT 0: Functions con‐
4)
(door interlocking)
figurable (Page 86) via
free function blocks
Parameterizable
INPUT 1: Configurable
(local sensor type)
as a local sensor type or
via function blocks
(FBLOCK) (Page 86)
Functions configurable
(Page 86) via free func‐
OPEN/CLOSE)
tion blocks (FBLOCK)
CLOSE DOOR
(pulse controlled)
OPEN DOOR
(pulse controlled)
ATD4xxW for industrial applications