Siemens SIDOOR ATD4 W Series System Manual page 190

Automatic door control units
Table of Contents

Advertisement

Controllers
5.9 Operation and configuration of the control unit
Parameter ID
Unit
p3680
mA
p3681
mA
Forces
p3682
N
p3683
N
p3684
N
p3685
N
You will find the corresponding factory settings and adjustment ranges (depending on the
motor used) for the driving parameters in section Profiles and adjustment ranges (Page 329).
Other parameters
Table 5-31
Other parameters
Parameter ID
Adjustment range
Sensor Module
p4600
0 ≙ inactive
1 ≙ ESPE
2 ≙ DCOPS
3 ≙ pressure sensitive
edge
4 ≙ Light barrier (as of
V1.14)
p4601
20 ... 5000
p4610
0 ... 30000
0 ≙ "AND0" discrepancy
analysis deactivated
p4611
10 ... 30000
0 ≙ discrepancy analysis
"AND2" deactivated
Faults and alarms
r2100
r2102
0 ≙ special motor
1 ≙ M2
2 ≙ M3 / MDG3
3 ≙ M4 / MDG4
4 ≙ M5 / MDG5
255 ≙ unknown motor
Display and operation
188
Parameter name
Idle torque CLOSE
Peak torque close
Static force limit open
Static force limit close
Limit force end close
Static NDG-force (reduced)
Factory set‐
ting
0
30
400
400
Description
Continuous torque in closed position. The current gener‐
ates a continuous torque against the end position of the
door in the closing direction.
Peak torque close in closed position for approx. 2 s
Static force limit open
Static force limit close
Limit force end in the closing direction
Force in NDG mode in the opening and closing directions
Unit
Description
Local sensor type
ms
Discrepancy time in the function test of the OSSD sys‐
tem
ms
Discrepancy analysis time of the input monitoring
block FBLOCK "AND0"
ms
Discrepancy analysis time of the input monitoring
block FBLOCK "AND2"
Status code
ASCII code of the 7-segment display (see section Fig‐
ure 5-4 Sequential control state graph (Page 163))
Connected motor
System Manual, 06/2022, A5E51901827B AA
ATD4xxW for industrial applications