Connecting and commissioning

10.3 Connecting a geared motor to the control unit

10.3
Connecting a geared motor to the control unit
Connecting a geared motor to the control unit
1. Connect the motor connector with slot X7 on the SIDOOR ATD4xxW control unit
Note
The X6 control inputs plug is not plugged in during commissioning in order to prevent
uncontrolled movements.
2. Plug the motor cable connector into the SIDOOR MDG3, MDG4 or MDG5 geared motor.
– Remove the protective cover from the connection plug of the motor.
– Plug the round connector of the cable (6FB1104-0AT..-0CB.) into the motor plug socket
296
X7
(6FB1103-0AT1.-.M..). Ensure that the round connector is in the correct position. Turn the
round connector so that the outer code rings match the code rings on the plug socket.