Sidoor M3 L / R - Siemens SIDOOR ATD4 W Series System Manual

Automatic door control units
Table of Contents

Advertisement

Appendices
A.2 Profiles and adjustment ranges
A.2.2

SIDOOR M3 L / R

Table A-45
Parameters and setting ranges for SIDOOR M3 L / R
Parameter
Slow end distance open
Slow start distance open
Slow start distance close
Slow end distance close
Maximum speed open
Slow end speed open
Slow start speed open
Slow initial speed open
Maximum speed close
Slow start speed close
Slow end speed close
Slow initial speed close
NDG speed (reduced)
Acceleration ramp open
Deceleration ramp open
Reversal ramp open/close
Acceleration ramp close
Deceleration ramp CLOSE
330
Parameter ID
Unit
p3660
mm
p3661
mm
p3662
mm
p3663
mm
p3664
mm/s
p3665
mm/s
p3666
mm/s
p3667
mm/s
p3668
mm/s
p3669
mm/s
p3670
mm/s
p3671
mm/s
p3672
mm/s
p3673
mm/s
p3674
mm/s
p3675
mm/s
p3676
mm/s
p3677
mm/s
Profile 1*
30
30
20
40
650
40
60
90
281
60
40
90
281
1300
2
2
600
1200
2
2
500
500
2
System Manual, 06/2022, A5E51901827B AA
Adjustment range
ATD4xxW
0 ... 100
0 ... 100
0 ... 100
0 ... 100
100 ... 650
30 ... 650 (as of
V1.03)
30 ... 90
30 ... 90
30 ... 90
100 ... 650
30 ... 650 (as of
V1.03)
30 ... 90
30 ... 90
30 ... 90
50 ... 650
30 ... 650 (as of
V1.03)
300 ... 1400
As of (V1.09): 250 ...
1400
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
300 ... 1400
As of (V1.09): 250 ...
1400
300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
ATD4xxW for industrial applications