SIDOOR functions
4.3 Extended functions
Control of the basic parameter editor via menu system
With the menu command "General setup -> Basic parameters", you can open basic parameters
editor in the menu (see also section "Navigation Structure in SIDOOR Service Tool (Page 274)").
As of V1.10:
If the menu command "Change Basic Parameters" is not selected with CR, the basic parameters
are only displayed.
If the menu command "Change Basic Parameters" was selected with CR, it changes to "Save Basic
Parameters" and the basic parameters can be changed.
After all basic parameters have been changed or confirmed with CR, you can select "Save basic
parameters". The basic parameters are saved and the menu command returns to "Change Basic
Parameters".
If not all basic parameters were changed or confirmed with CR with an initial commissioning or
after resetting the parameter memory via p91, an error message is displayed. Changes to the
parameter settings are discarded.
As of V1.14:
The basic parameters can be directly changed after selection with CR. When the menu level
"General setup -> Basic parameter" is left by using the "ESC" button, an "ESC -> Abort / CR -> Save"
query prompt is displaced. The changes to the basic parameter are rejected with the "ESC" basic
parameter, the changes are applied and saved with the "CR" button.
4.3.11

Masking of door commands (as of V1.12)

Description of function
With this function it is possible to mask door commands from the two door command sources
"Fieldbus" and "FBLOCK". In particular, masking is provided for the DCMD extension bits.
The masks can be used to define which bits of the door commands are still to be effective
according to Section (Page 319) and which are not.
108
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA