Operation - Siemens SIDOOR ATD4 W Series System Manual

Automatic door control units
Table of Contents

Advertisement

Optional additional units
8.1 SIDOOR SERVICE TOOL
Material damage
For this reason, only connect suitable SIDOOR accessories.
8.1.3

Operation

Parameters can be changed in both of the following menus:
• MAIN MENU > Quick setup > Parameter setting
• MAIN MENU > General setup > Profile parameters
Note
If the SIDOOR SERVICE TOOL is in the "Quick setup" or "General setup" menu, the door
commands of the controller are blocked by the command inputs of the terminal strip X6.
Key functions
Key
ESC
Operating principle
Action
1
2
3
4
272
CAUTION
Description
Enter key
Escape key
Menu selection key
Menu selection key
Select required parameter
Activate parameter for setting us‐
ing the Return key
Increase or decrease parameter
value
Accept parameter value by press‐
ing Return key again
Function
Jump to next menu below
Jump back to menu above
Increases a parameter value
Decreases a parameter value
Key
Remarks
Parameter value flashes
Displayed parameter value stops flashing af‐
ter acceptance.
System Manual, 06/2022, A5E51901827B AA