Controllers
5.9 Operation and configuration of the control unit
Example: Closing weight = 4 kg
Desired static force limit CLOSE = 150 N
The counterweight of 4 kg corresponds to a force of 40 N. The force limit then has to be adjusted
to 150 N – 40 N = 110 N.
In the factory setting, the closing force is preset to a minimum value (see section Profiles and
adjustment ranges (Page 329)).
Limit force end CLOSE
This force serves to overcome the cutter distance in the closing direction.
A higher force is often required to overcome the cutter distance than for the rest of the distance
the door travels.
This parameter is effective in the closing direction when the door is within the cutter distance.
Adjustment ranges
The parameter can be adjusted in accordance with the adjustment ranges of the parameters (see
section Profiles and adjustment ranges (Page 329)). The value of the parameter must be selected
so that the cutter distance is overcome in the closing direction.
In the factory setting, the closing force is preset to a minimum value (see section Profiles and
adjustment ranges (Page 329)).
5.9.4.3

Parameter assignment

The tables below show all the parameters that are available via the PKW interface. The
parameters are generally subdivided into:
• Driving parameters
• Fieldbus parameters
• Other parameters
• Calibration and function parameters
• Obstruction and reversing parameters
• FBLOCK parameters
• Basic parameters
Note
Write-protected parameters (read only) are indicated in the documentation by an "r" before the
parameter number.
Read / write parameters can be changed, and are indicated by a "p" before the parameter number.