Installing/Mounting
3.3 Control Unit installation
Table 3- 9
Summary of dimensions and tightening torques
Frame size
Dimensions (height x width x depth)
with Operator Panel
A
mm
460 x 154 x 264
inch
18.11 x 6.06 x 10.39
B
mm
540 x 180 x 264
inch
21.25 x 7.09 x 10.39
C
mm
620 x 230 x 264
inch
24.40 x 9.05 x 10.39
D
mm
640 x 320 x 344
inch
25.19 x 12.59 x 13.54
E
mm
751 x 320 x 344
inch
29.56 x 12.59 x 13.54
F
mm
915 x 410 x 431
inch
36.02 x 16.14 x 16.96
3.3
Control Unit installation
Fitting the CU to the PM FSA ... FSF
Note
Memory card
If a memory card is to be used with the Control Unit (CU), then the memory card must be
inserted into the CU prior to being fitted on the Power Module (PM). Once the CU is fitted to
the PM it is not possible to insert a memory card into the CU.
The Control Unit (CU) is snapped onto the Power Module as shown in the figure below. The
CU is fitted in the following sequence:
30
without Operator Panel
460 x 154 x 249
18.11 x 6.06 x 9.80
540 x 180 x 249
21.25 x 7.09 x 9.80
620 X 230 X 249
24.40 x 9.05 x 9.80
640 x 320 x 329
25.19 x 12.59 x 12.95
751 x 320 x 329
29.56 x 12.59 x 12.95
915 x 410 x 416
36.02 x 16.14 x 16.37
Hardware Installation Manual, 2010-07-02, A5E02923635A AB
Fixing methods
4 x M4 bolts
4 x M4 nuts
4 x M4 washers
4 x M5 bolts
4 x M5 nuts
4 x M5 washers
4 x M8 bolts
4 x M8 nuts
4 x M8 washers
Tightening torques
2.5 Nm (22 lbf.in)
13.0 Nm (115 lbf.in)
Power Module PM230 IP55