Accessories
11.2 DRIVE-CLiQ coupling
11.1.5
Technical data
Table 11- 1
Weight
Degree of protection
to IEC 60529
11.2
DRIVE-CLiQ coupling
11.2.1
Description
The DRIVE-CLiQ coupling is used to connect two DRIVE-CLiQ cables in accordance with
degree of protection IP67 acc. to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
Information on the permissible cable length can be found in Section "DRIVE-CLiQ signal
cables (Page 301)".
11.2.2
Safety information
NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when incorrect or unreleased
DRIVE-CLiQ cables are used.
• Only use suitable DRIVE-CLiQ cables that have been released by Siemens for the
284
Technical data of DRIVE-CLiQ cabinet bushings
Unit
kg
respective application.
6SL3066-2DA00-0AA0
DRIVE-CLiQ
0.165
IP54 outside the control cabinet
IP20 or IPXXB inside the con-
trol cabinet
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
6FX2003-0DT67
M12
0.035
IP67