X500-X505 Drive-Cliq Interfaces; X524 Electronics Power Supply - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components
9.3 DRIVE-CLiQ Hub Module External DME20
9.3.3.2

X500-X505 DRIVE-CLiQ interfaces

Table 9- 20
Connector
type
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (6 units), article number: 6SL3066-4CA01-0AA0
Note
Only MOTION-CONNECT DRIVE-CLiQ cables may be used to establish connections.
The maximum length of MOTION-CONNECT 500 is 100 m and for MOTION-CONNECT
800PLUS cables, 75 m.
9.3.3.3

X524 Electronics power supply

Table 9- 21
232
X500-X505: DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
DRIVE-CLiQ socket
X524: Electronics power supply
Pin
Designation
1
Electronics power supply
2
Electronics power supply
3
Electronics ground
4
Electronics ground
5
Not connected
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Technical data
The supply voltage of 20.4 V ... 28.8 V
refers to the (terminal) voltage at the
DME20. This must be taken into account
when selecting the cable cross-section
and supply cable lengths.
Pins 1 and 2: jumpered internally
Pins 3 and 4: jumpered internally
Type: 5-pin socket
max. connectable cross-section:
4 x 0.75 mm
2
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5

Advertisement

Table of Contents
loading

Table of Contents