Encoder System Interface - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Encoder system connection
10.3 Sensor Module External SME20
10.3.3.4

Encoder system interface

Table 10- 16 Encoder system interface SME20
Connector kit:
Measuring current via temperature sensor connection: 2 mA
Blanking cover for encoder system interface: Pöppelmann GmbH & Co. KG, Lohne,
Article number: GPN 300 F211
These connections do not have protective separation!
1)
Accuracy of the temperature measurement:
2)
- KTY: ±7 °C (including evaluation)
- PT1000: ±5 °C (PT1000 tolerance class B according to DIN EN 60751 including evaluation)
- PTC: ±5 °C (including evaluation)
Connecting cable: Article number 6FX8002-2CA88-....
3)
266
Pin
Signal name
1
B*
2
P5
3
R
4
R*
5
A
6
A*
7
-Temp
1) 2)
8
B
9
+Temp
10
M
11
M
12
P5
12 pole, article number: 6FX2003-0SA12
Technical data
Inverse incremental signal B
Encoder power supply
Reference signal R
Inverse reference signal R
Incremental signal A
Inverse incremental signal A
Temperature sensor connection
KTY84-1C130 / PT1000 / PTC
Incremental signal B
Temperature sensor connection
1) 2)
KTY84-1C130 / PT1000 / PTC
Ground, encoder power supply
Ground, encoder power supply
Encoder power supply
3)
3)
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5

Advertisement

Table of Contents
loading

Table of Contents