Siemens SINAMICS S120 Combi Equipment Manual page 303

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Table 12- 8
Approved power cables for motors connected to the S120 Combi - prefabricated
Motor
1PH8 with terminal box
1PH8 with terminal box
1PH8 with terminal box
1FT7/1FK7 with quick release
1PH8 with connector with fast release 5DF11
1PH8 with connector with fast release 5CF12
1PH8 with connector
without fast release
x: 5 = MC500, 8 = MC800
Danger to life due to missing emergency motor shutdown option
If the motor holding brake is not connected or is incorrectly connected, serious physical
injuries can occur.
• Only connect motors with a safe electrically isolated holding brake. The brake cores
• If the motor power cable is connected to intermediate terminals, the power cables and
Note
If the connecting cables for a 24 V motor holding brake are included in the power cable, then
only the specified cables must be used. These cables must have a separate shield for the
24 V and must be suitable for safe electrical separation.
The cable shield of the motor holding brake conductors must be connected at both ends.
Note
In order that the specified EMC limit values (EN 61800-3) are maintained, only shielded type
MC500 and MC800 power cables must be used. The permissible cable length is 25 m for
rated output currents I
The total cable length for the complete drive line-up is 175 m.
SINAMICS S120 Combi
Manual, (GH9), 07/2016, 6SL3097-4AV00-0BP5
Article number
6FXx002-
5CE02
5CE04
5CE06
5CF10
5DF10
5CF13
WARNING
must also be safely electrically isolated.
brake cables must be routed separately (≥ 300 mm) from each other.
from 5 A to 30 A.
n
Description
Power cable 1PH808 4 x 2.5
Power cable 1PH810 4 x 4
Power cable 1PH813 4 x 6
Power cable 4 x 1.5 GR.1 SC
Power cable 4 x 1.5 + 2 x 1.5 GR.1 SC
Power cable 4 x 2.5 GR.1.5 SC
Power cable 4 x 4 GR.1.5 SC
Power cable 4 x 10 GR.3
Cabinet design and EMC
12.7 Connection system
D
max
6FX5
6FX8
10.0
12.1
11.4
13.2
13.6
16.0
8.4
10.4
10.8
12.9
10.0
12.1
11.4
13.2
20
19.4
303