Technical Data - Siemens SINAMICS S120 Equipment Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.2.3.7

Technical data

Table 7- 18
Article number
Suitable for Power Module (unit
rating)
I
thmax
Degree of protection
dV/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- to the Power Module
- load
- protective conductor
Max. permissible
cable length between dV/dt
reactor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage Peak Limiter
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- to the dv/dt reactor
- DC
- protective conductor
Dimensions
Width
Height
Depth
Weight, approx.
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Technical data, dV/dt filter plus Voltage Peak Limiter
6SL3000-
6SL3310-
A
kW
kW
kW
m
mm
mm
mm
kg
kW
kW
kW
mm
mm
mm
kg
Motor-side power components
2DE32-6AA0
1TE32-1AA. (110 kW)
1TE32-6AA. (132 kW)
260
IP00
0.701
0.729
0.78
M10
M10
M6
300 (shielded)
450 (unshielded)
410
370
229
66
0.029
0.027
0.025
M8
M8
M8
265
263
190
6
7.2 Chassis
2DE35-0AA0
1TE33-1AA. (160 kW)
1TE33-8AA. (200 kW)
1TE35-0AA. (250 kW)
490
IP00
0.874
0.904
0.963
M12
M12
M6
460
370
275
122
0.042
0.039
0.036
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
392
285
210
16
213

Advertisement

Table of Contents
loading