8.4.2.14
S5 DIP switch
DIP switch S5 is used to switch the analog input between voltage input and current input. It
is located under the blanking cover (see CU310-2 PN Interface Overview (Page 230).)
Table 8- 36
DIP switch S5 - switchover between voltage/current
8.4.2.15
DIAG button
The DIAG pushbutton is reserved for service functions.
8.4.2.16
RESET button
Pressing the RESET button restarts the CU310-2 DP after expiry of a preset time. A data
backup is run at the same time. This means that all the settings are retained.
8.4.2.17
Memory card
Inserting the memory card
Use only memory cards manufactured by Siemens to run the CU310-2 DP.
Insert the memory card into the CU310-2 DP so that the arrow on the card's label (on the
left, next to the word Siemens) points to the arrow on the device.
AC Drive
Manual, 06/2019, 6SL3097-5AL00-0BP1
Control Units, Control Unit Adapters and operating components
Switch
Function
S5.0
Switchover between voltage (U) / current (I)
S5.1
Not assigned
8.4 Control Unit CU310-2 DP (PROFIBUS)
267