Siemens SINAMICS S120 Equipment Manual page 318

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Supplementary system components and encoder system integration
9.1 Sensor Modules
X500 DRIVE-CLiQ interface
Table 9- 12
Connector
type
The blanking cover for the DRIVE-CLiQ port is included in the scope of delivery.
Blanking covers (50 x) Article No:: 6SL3066-4CA00-0AA0
X520 encoder system interface
Table 9- 13
X520: Encoder system interface
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Connector type:
15-pin Sub-D socket
Measuring current via temperature sensor connection: 2 mA
1) Accuracy of the temperature measurement:
- KTY: ±7 °C (including evaluation)
- Pt1000: ±5 °C (Pt1000 tolerance class B according to EN 60751 including evaluation)
- PTC: ±5 °C (including evaluation)
316
X500: DRIVE-CLiQ interface
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
Reserved, do not use
B
M (0 V)
DRIVE-CLiQ socket
Signal name
+Temp
1)
Clock
Clock*
P encoder 5 V / 24 V
P encoder 5 V / 24 V
P sense
M encoder (M)
- Temp
1)
M sense
R
R*
B*
B
A* / data*
A / data
Technical data
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
-
Electronics ground
Technical data
KTY84-130 / Pt1000 / PTC temperature sensors
SSI clock
Inverse SSI clock
Encoder power supply
Sense input encoder power supply
Ground, encoder power supply
KTY84-130 / Pt1000 / PTC temperature sensors
Ground sense input
Reference signal R
Inverse reference signal R
Inverse incremental signal B
Incremental signal B
Inverted incremental signal A/inverted SSI data
Incremental signal A/SSI data
Manual, 06/2019, 6SL3097-5AL00-0BP1
AC Drive

Advertisement

Table of Contents
loading

Table of Contents