Huawei FusionServer Pro 2288H V5 Technical Manual

Huawei FusionServer Pro 2288H V5 Technical Manual

Hide thumbs Also See for FusionServer Pro 2288H V5:

Advertisement

Huawei FusionServer Pro 2288H V5 Server
V100R005
Technical White Paper
Issue
12
Date
2020-04-20
HUAWEI TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei FusionServer Pro 2288H V5

  • Page 1 Huawei FusionServer Pro 2288H V5 Server V100R005 Technical White Paper Issue Date 2020-04-20 HUAWEI TECHNOLOGIES CO., LTD.
  • Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 3: About This Document

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper About This Document About This Document Purpose This document describes the 2288H V5 rack server in terms of features, structure, specifications, and component compatibility. Intended Audience This document is intended for: ●...
  • Page 4 Huawei FusionServer Pro 2288H V5 Server Technical White Paper About This Document Symbol Description Supplements the important information in the main text. NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. Change History...
  • Page 5: Table Of Contents

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper Contents Contents About This Document........................ ii 1 Overview............................1 2 Features............................. 2 3 Physical Structure........................5 4 Logical Structure........................7 5 Hardware Description......................9 5.1 Front Panel....................................9 5.1.1 Appearance.................................... 9 5.1.2 Indicators and Buttons..............................11 5.1.3 Ports.......................................
  • Page 6 Huawei FusionServer Pro 2288H V5 Server Technical White Paper Contents 5.7.2 PCIe Slots....................................48 5.7.3 PCIe Slot Description................................ 51 5.8 PSUs......................................54 5.9 Fans......................................55 5.10 Boards..................................... 56 5.10.1 Mainboard..................................56 5.10.2 Drive Backplane................................58 6 Product Specifications......................64 6.1 Technical Specifications..............................64 6.2 Environmental Specifications............................
  • Page 7: Overview

    Technical White Paper 1 Overview Overview Huawei FusionServer Pro 2288H V5 (2288H V5) is a new-generation 2U 2-socket rack server designed for Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom applications. The 2288H V5 is ideal for IT core services, cloud computing, high-performance computing, distributed storage, big data processing, enterprise or telecom applications, and other complex workloads.
  • Page 8: Features

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 2 Features Features Performance and Scalability ® ® ● Powered by two Intel Xeon Scalable Skylake or Cascade Lake processors, the server provides up to 28 cores, 3.8 GHz frequency, a 38.5 MB L3 cache, and two 10.4 GT/s UPI links between the processors, which deliver supreme...
  • Page 9 ● Huawei provides a three-year warranty for parts replacement and onsite repair for the servers used in China. Huawei provides a 10-hour-a-day, 7-day- a-week support program. Service requests will be handled the next business day. Optional service upgrades are available.
  • Page 10 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 2 Features ● Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer overflow attacks when working with a supported OS. ● Intel Trusted Execution Technology enhances security using hardware-based defense against malicious software attacks, allowing applications to run independently.
  • Page 11: Physical Structure

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 3 Physical Structure Physical Structure Figure 3-1 Physical structure of a 2288H V5 with 12 x 3.5" drives (example) I/O module 1 I/O module 2 PSUs I/O module 3 Chassis Supercapacitor holders...
  • Page 12 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 3 Physical Structure TPM/TCM Memory modules Processors Heat sinks Issue 12 (2020-04-20) Copyright © Huawei Technologies Co., Ltd.
  • Page 13: Logical Structure

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 2288H V5 logical structure ® ® ● The server supports one or two Intel Xeon Scalable processors. ● The server supports up to 24 memory modules.
  • Page 14 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 4 Logical Structure – Two GE electrical LOM ports ● The server uses Hi1710 management chip and supports a video graphic array (VGA) port, a management network port, and a debug serial port.
  • Page 15: Hardware Description

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Hardware Description 5.1 Front Panel 5.2 Rear Panel 5.3 Processor 5.4 Memory 5.5 Storage 5.6 Network 5.7 I/O Expansion 5.8 PSUs 5.9 Fans 5.10 Boards 5.1 Front Panel 5.1.1 Appearance...
  • Page 16 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Drives (Optional) Built-in DVD drive Slide-out label plate (with an SN label) ● 12 x 3.5" drive configuration Figure 5-2 Front view Drives Slide-out label plate (with an SN label) ●...
  • Page 17: Indicators And Buttons

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Drives Slide-out label plate (with an SN label) ● 25 x 2.5" drive configuration Figure 5-5 Front view Drives Slide-out label plate (with an SN label) 5.1.2 Indicators and Buttons Positions ●...
  • Page 18 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-7 Indicators and buttons on the front panel 10GE LOM port 1 10GE LOM port 2 connection status connection status indicator indicator GE LOM port 1 GE LOM port 2...
  • Page 19 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-9 Indicators and buttons on the front panel 10GE LOM port 1 10GE LOM port 2 connection status connection status indicator indicator GE LOM port 1 GE LOM port 2...
  • Page 20 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Indicator and Button Description Table 5-1 Indicators and buttons on the front panel Silkscreen Indicator/ Description Button Fault ● ---: The device is operating normally. diagnosis LED ● Fault code: A component is faulty.
  • Page 21: Ports

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Silkscreen Indicator/ Description Button Health status ● Off: The device is powered off or is faulty. indicator ● Blinking red at 1 Hz: A major alarm has been generated on the system.
  • Page 22 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-11 Ports on the front panel USB 2.0 ports USB 3.0 port VGA port ● 12 x 3.5" drive configuration Figure 5-12 Ports on the front panel USB 2.0 ports...
  • Page 23: Rear Panel

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description USB 2.0 ports USB 3.0 port VGA port ● 25 x 2.5" drive configuration Figure 5-15 Ports on the front panel USB 2.0 ports Port Description Table 5-2 Ports on the front panel...
  • Page 24: Appearance

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description 5.2.1 Appearance Figure 5-16 Rear view I/O module 1 I/O module 2 I/O module 3 PSU 2 PSU 1 (Optional) FlexIO card ● I/O modules 1, 2 and 3 can be configured with drive modules or PCIe riser modules.
  • Page 25 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Connection status Data transmission rate indicator/Data indicator for a 10GE transmission status optical port indicator for a 10GE optical port Data transmission rate Connection status indicator for a 10GE...
  • Page 26 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Indicator Description Table 5-3 Indicators on the rear panel Indicator Description PSU indicator ● Off: No power is supplied. ● Blinking green at 1 Hz: – The input is normal, the server is in standby state, and the PSU is in MV6 mode (output voltage is 6.7 V).
  • Page 27: Ports

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Indicator Description Connection status ● Off: The network port is not connected. indicator/Data ● Blinking green: Data is being transmitted. transmission status ● Steady green: The network port is properly indicator for a 10GE connected.
  • Page 28 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description (Optional) 10GE optical (Optional) 10GE optical port (LOM port 1) port (LOM port 2) (Optional) 10GE electrical (Optional) 10GE electrical port (LOM port 1) port (LOM port 2)
  • Page 29 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Port Type Quantity Description Management 1000BASE-T Used for server management. network port NOTE The management network port is a GE port that supports 100 Mbit/s and 1000 Mbit/s auto- negotiation.
  • Page 30: Processor

    If only one processor is required, install it in socket CPU1. ● The same model of processors must be used in a server. ● Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used.
  • Page 31: Memory

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-19 Processor positions 5.4 Memory 5.4.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module. Figure 5-20 Memory identifier Issue 12 (2020-04-20) Copyright ©...
  • Page 32: Memory Subsystem Architecture

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description callout Description Definition Capacity of the memory ● 8 GB module ● 16 GB ● 32 GB ● 64 GB ● 128 GB Number of ranks of the ●...
  • Page 33: Memory Compatibility

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot DIMM011(H) C (primary) DIMM020(C) DIMM021(I) D (primary) DIMM030(D) DIMM031(J) E (primary) DIMM040(E) DIMM041(K) F (primary) DIMM050(F) DIMM051(L) CPU 2 A (primary) DIMM100(A) DIMM101(G) B (primary)
  • Page 34 Maximum operating speed of a memory module ● The DDR4 memory modules of different types (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together. ● Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used.
  • Page 35: Memory Installation Guidelines

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description A quad-rank LRDIMM generates the same electrical load as a single-rank RDIMM on a memory bus. Table 5-7 DDR4 memory specifications Parameter Specifications Maximum capacity per DDR4 memory module (GB)
  • Page 36: Memory Installation Positions

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description ▪ The channels can have different online spare configurations. ▪ Each populated channel must have a spare rank. – Memory mirroring mode ▪ Comply with the general installation guidelines.
  • Page 37: Memory Protection Technologies

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-22 DDR4 memory installation guidelines (1 processor) Figure 5-23 DDR4 memory installation guidelines (2 processors) 5.4.6 Memory Protection Technologies The following memory protection technologies are supported: ●...
  • Page 38: Storage

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description ● Memory Address Parity Protection ● ADDDC ● Memory Demand/Patrol Scrubbing ● Data Scrambling ● ADDDC+1 5.5 Storage 5.5.1 Drive Configurations Table 5-8 Drive configurations Configuratio Maximum Maximum...
  • Page 39 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Drive Front Drives Rear Drives Built-in Management Drives Mode 12 x 3.5" ● I/O 1 x RAID drive EXP module 1: controller ● Slots 0 to ●...
  • Page 40 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Drive Front Drives Rear Drives Built-in Management Drives Mode 12 x 3.5" ● I/O 2 x RAID drive EXP module 1: controller ● Slots 0 to...
  • Page 41 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Drive Front Drives Rear Drives Built-in Management Drives Mode 12 x 3.5" ● I/O 1 x RAID drive pass- module 1: controller ● Slots 0 to...
  • Page 42 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Drive Front Drives Rear Drives Built-in Management Drives Mode 12 x 3.5" ● I/O 2 x RAID drive pass- module 3: controller ● Slots 0 to ●...
  • Page 43 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Drive Front Drives Rear Drives Built-in Management Drives Mode 25 x 2.5" ● I/O 1 x RAID drive EXP module 1: controller ● Slots 0 to...
  • Page 44: Drive Numbering

    (slots 0 to 7). The PCH supports only SATA drives. ● h: Every eight front drives require a RAID controller card. A maximum of three RAID controller cards are supported. ● Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used.
  • Page 45 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-25 Drive numbering ● 12 x 3.5" drive EXP configuration 2 Figure 5-26 Drive numbering ● 12 x 3.5" drive pass-through configuration 1 Issue 12 (2020-04-20) Copyright © Huawei Technologies Co., Ltd.
  • Page 46 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-27 Drive numbering ● 12 x 3.5" drive pass-through configuration 2 Figure 5-28 Drive numbering ● 12 x 3.5" drive pass-through configuration 3 Issue 12 (2020-04-20) Copyright © Huawei Technologies Co., Ltd.
  • Page 47 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-29 Drive numbering ● 20 x 2.5" (8 x SAS/SATA + 12 x NVMe) drive configuration Figure 5-30 Drive numbering ● 24 x 2.5" drive configuration Issue 12 (2020-04-20)
  • Page 48: Drive Indicators

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-31 Drive numbering ● 25 x 2.5" drive configuration Figure 5-32 Drive numbering 5.5.3 Drive Indicators SAS/SATA Drive Indicators Figure 5-33 SAS/SATA drive indicators Issue 12 (2020-04-20)
  • Page 49 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Table 5-9 Description of SAS/SATA drive indicators Activity Indicator Fault Indicator Description (Green) (Yellow) Steady on The drive is in position. Blinking at 4 Hz Data is being read or written normally, or data on the primary drive is being rebuilt.
  • Page 50: Raid Controller Card

    The NVMe drive is faulty. 5.5.4 RAID Controller Card The RAID controller card supports RAID configuration, RAID level migration, and drive roaming. ● Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used. ●...
  • Page 51 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description ● Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used. Table 5-12 FlexIO cards supported by the 2288H V5 (example)
  • Page 52 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-37 SM233 network port indicators ● SM251 with two 56G IB optical ports Figure 5-38 SM251 network port indicators ● SM252 with one 56G IB optical port Figure 5-39 SM252 network port indicators ●...
  • Page 53: I/O Expansion

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Port Type Indicator Description 10GE electrical Transmission rate ● Off: The data transmission rate is port indicator 10/100 Mbit/s. ● Steady green: The data transmission rate is 10 Gbit/s.
  • Page 54: Pcie Cards

    Technical White Paper 5 Hardware Description 5.7.1 PCIe Cards PCIe cards provide ease of expandability and connection. ● Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used. 5.7.2 PCIe Slots...
  • Page 55 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-42 PCIe riser module 1 ● PCIe riser module 2 (universal) – Provides PCIe slots 1, 2, and 3 when installed in I/O module 1. – Provides PCIe slots 4, 5, and 6 when installed in I/O module 2.
  • Page 56 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description ● PCIe riser module 3 (for ES3000 V3 SSD cards only) – Provides PCIe slots 1, 2, and 3 when installed in I/O module 1. – Provides PCIe slots 4, 5, and 6 when installed in I/O module 2.
  • Page 57: Pcie Slot Description

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description ● PCIe riser module 5 Provides PCIe slots 7 and 8 when installed in I/O module 3. Figure 5-46 PCIe riser module 5 ● PCIe riser module 6 Provides PCIe slot 7 when installed in I/O module 3.
  • Page 58 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Table 5-14 PCIe slot description PCIe PCIe Conne Port Root Device Slot Slot Stand ctor Width Port (B/D/ Size ards Width (B/D/ RAID CPU 1 PCIe Port1C 17/02/...
  • Page 59 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Device Slot Slot Stand ctor Width Port (B/D/ Size ards Width (B/D/ Slot 4 CPU 2 PCIe ● 2- Port1A 85/00/ 86/00/ FHFL slot ●...
  • Page 60: Psus

    The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs with dual input live wires. ● Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used.
  • Page 61: Fans

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description For a server configured with one or two 1500 W Platinum AC PSUs: ● When the input voltage is from 100 V AC to 132 V AC, the output power drops to 1000 ●...
  • Page 62: Boards

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description 5.10 Boards 5.10.1 Mainboard Figure 5-50 2288H V5 mainboard USB 3.0 port (USB 3.0 UID indicator (D6020) CONN/J169) Serial port Management network port GE electrical port GE electrical port Issue 12 (2020-04-20) Copyright ©...
  • Page 63 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description VGA connector (VGA 10GE optical port (10GE CONN/J112) PORT2/J132) or 10GE electrical port (10GE PORT2/J101) 10GE optical port (10GE VROC key port (J130) PORT1/J131) or 10GE electrical port (10GE...
  • Page 64: Drive Backplane

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description CPU 2 slimline B PSU 2 connector (J157) connector (CPU2 SLIMLINE B/J139) PSU 1 connector (J156) Built-in drive low-speed signal connector (INNER HDD BP/J122) Left mounting ear Jumper (J176)
  • Page 65 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Front VGA connector Backplane signal cable (J26) connector (J1) DVD drive power mini-SAS HD connector connector (J11) (PORT B/J29) mini-SAS HD connector Power connector (J24) (PORT A/J28) ●...
  • Page 66 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description mini-SAS HD connector Indicator signal cable (PORT A/J28) connector (J31) Power connector (J24) ● 20 x 2.5" (8 x SAS/SATA + 12 x NVMe) drive backplane Figure 5-54 20 x 2.5" (8 x SAS/SATA+12 x NVMe) drive backplane (BOM...
  • Page 67 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description mini-SAS HD connector mini-SAS HD connector (PORT 2B/J31) (PORT 2A/J30) mini-SAS HD connector Backplane signal cable (PORT 1B/J29) connector (J1) mini-SAS HD connector Power connector (J24) (PORT 1A/J28) ●...
  • Page 68 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Indicator signal cable connector (J35) Built-in-Drive Backplane ● Built-in-drive backplane Figure 5-58 Built-in-drive backplane (BOM 03024MBJ) mini-SAS HD connector Backplane signal cable (PORT A/J3) connector (INNER HDD BP/J1)
  • Page 69 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 5 Hardware Description Figure 5-60 4 x 2.5" drive backplane (BOM 03024BPV) Power connector (REAR mini-SAS HD connector BP POWR3/J22) (Port A/J2) Slimline A connector Slimline B connector (SLIMLINE A/J8) (SLIMLINE B/J9)
  • Page 70: Product Specifications

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical specifications Category Specifications Form factor 2U rack server Chipset ® ®...
  • Page 71 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 6 Product Specifications Category Specifications Memory Supports 24 memory modules of the following types: ● Up to 24 DDR4 memory modules ● Max. 2933 MT/s memory speed ● RDIMM and LRDIMM support ●...
  • Page 72 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 6 Product Specifications Category Specifications Storage Supports a variety of drive configurations. For details, 5.5.1 Drive Configurations. ● Supports two M.2 SSDs. – M.2 SSDs are supported only when the server is configured with an Avago SAS3004iMR RAID controller card.
  • Page 73 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 6 Product Specifications Category Specifications For details about the RAID controller card, see Huawei V5 Server RAID Controller Card User Guide. ● Supports SAS HBA cards or SAS RAID controller card (with a 1 GB, 2 GB, or 4 GB cache) to improve storage performance and data security.
  • Page 74 PCIe cards. For details, see 5.7.2 PCIe Slots 5.7.3 PCIe Slot Description. ● Support Huawei proprietary PCIe SSD cards to bolster I/O performance for applications such as searching, caching, and download services. ● Supports GPU cards. NOTE The preceding information is for reference only. Use the...
  • Page 75: Environmental Specifications

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 6 Product Specifications Category Specifications Video card An SM750 video chip with 32 MB display memory is integrated on the mainboard. The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors.
  • Page 76 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 6 Product Specifications Category Specifications Relative humidity (RH, ● Operating humidity: 8% to 90% non-condensing) ● Storage humidity (≤ 72 hours): 5% to 95% ● Long-term storage humidity (> 72 hours): 30% to ●...
  • Page 77: Physical Specifications

    – Cabinet width: 482.6 mm (19 in.) – Cabinet depth ≥ 1000 mm (39.37 in.) ● Requirements for guide rail installation: – L-shaped guide rails: apply only to Huawei cabinets. – Static rail kit: applies to cabinets with a distance of 543.5 mm to 848.5 mm (21.40 in.
  • Page 78 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 6 Product Specifications Category Description Weight in full ● Maximum net weight: configuration – Server with 8 x 2.5" front drives + 4 x 2.5" rear drives: 25.1 kg (55.35 lb) –...
  • Page 79: Software And Hardware Compatibility

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 7 Software and Hardware Compatibility Software and Hardware Compatibility Use the Intelligent Computing Compatibility Checker to obtain information about the operating systems and hardware supported. NO TICE Do not use incompatible components. Otherwise, the server may fail to work properly.
  • Page 80: Safety Instructions

    Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference. Personal Safety ● Only personnel certified or authorized by Huawei are allowed to install the hardware. ● Stop any operation that may cause personal injury or equipment damage, report the problem to a project supervisor immediately, and take protective measures.
  • Page 81 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 8 Safety Instructions Figure 8-1 Protective clothing ● Before touching a device, ensure that you are wearing ESD clothing and ESD gloves (or wrist strap), and remove any conductive objects (such as watches and jewelry).
  • Page 82 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ● Exercise caution when using tools that could cause personal injury. ● If the installation position of the device is above shoulder height, use a stacker to lift it.
  • Page 83: Maintenance And Warranty

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 8 Safety Instructions ● If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe GPUs and SSDs) separately. Intelligent Computing Compatibility Checker to obtain information abut the components supported by a node or server.
  • Page 84: System Management

    Technical White Paper 9 System Management System Management The server uses Huawei proprietary intelligent Baseboard Management Controller (iBMC) to implement remote server management. The iBMC complies with Intelligent Platform Management Interface (IPMI) 2.0 and provides highly reliable hardware monitoring and management.
  • Page 85 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 9 System Management Feature Description System watchdog Supports BIOS POST, OS watchdog, and automatic system reset after fault timeout. Users can enable or disable these features individually. Boot device configuration Supports out-of-band configuration for boot devices.
  • Page 86: Certifications

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe RoHS 2011/65/EU, EN 50581:2012 Europe REACH EC NO. 1907/2006 Europe Safety: EN 60950-1:2006+A11:2009+A1:2010+A12: 2011 EMC: ● EN 55022:2010 ● CISPR 22:2008 ●...
  • Page 87 Huawei FusionServer Pro 2288H V5 Server Technical White Paper 10 Certifications Country/Region Certification Standards America NTRL-UL UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment- Safety-Part 1: General Requirements) CSA C22.2 No.60950-1-07, 2nd Edition, 2011-12 (Information Technology Equipment-Safety-Part 1:General Requirements) Canada...
  • Page 88: A Appendix

    A Appendix Appendix A.1 Product SN The serial number (SN) on the slide-out label plate uniquely identifies a device. The SN is required when you contact Huawei technical support. Figure A-1 SN example Table A-1 SN description Callout No. Description SN ID (two characters), which is 21.
  • Page 89 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Callout No. Description Year and month (two characters). ● The first character indicates the year. – Digits 1 to 9 indicate years 2001 to 2009, respectively. – Letters A to H indicate years 2010 to 2017, respectively.
  • Page 90: Operating Temperature Limitations

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix A.2 Operating Temperature Limitations Table A-2 Operating temperature limitations Configuratio Max. 30°C Max. 35°C Max. 40°C Max. 45°C (86°F) (95°F) (104°F) (113°F) 8 x 2.5" drive ● All options...
  • Page 91 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Configuratio Max. 30°C Max. 35°C Max. 40°C Max. 45°C (86°F) (95°F) (104°F) (113°F) 12 x 3.5" ● All options Options not Options not ● Not drive pass- supported supported:...
  • Page 92: Nameplate

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix ● When a single fan is faulty: ● The maximum operating temperature is 5°C (41°F) lower than the rated value. ● System performance will be affected if GPU cards are configured.
  • Page 93 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Module Feature Description Memory Address Parity Detects memory command and Protection address errors. Memory Demand and Corrects errors upon detection. If these Patrol Scrubbing errors are not corrected promptly, uncorrectable errors may occur.
  • Page 94: Sensor List

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Module Feature Description Architected Error Records With the enhanced machine check architecture (eMCA) feature, the BIOS collects error information from hardware registers in compliance with UEFI specifications, sends the error...
  • Page 95 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Sensor Description Component N Core Rem CPU core temperature N indicates the CPU number. The value is 1 or N DTS CPU DTS value N indicates the CPU number. The value is 1 or...
  • Page 96 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Sensor Description Component N DDR VDDQ2 1.2 V DIMM voltage Mainboard N indicates the CPU number. The value is 1 or N VSA CPU VSA voltage Mainboard N indicates the CPU number.
  • Page 97 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Sensor Description Component Disks Temp Drive maximum Drive temperature Power PSU input power N indicates the PSU number. The value is 1 or PCH Status PCH chip fault diagnosis...
  • Page 98 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Sensor Description Component Mngmnt Health Management subsystem Management module health status UID Button UID button status Mainboard PwrOk Sig. Drop Voltage dip status Mainboard PwrOn TimeOut Power-on timeout Mainboard...
  • Page 99 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Sensor Description Component N Temp Status PSU presence N indicates the PSU number. The value is 1 or DISK Drive status Drive N indicates the drive slot number. The value ranges from 0 to 24 or from 36 to 47.
  • Page 100 Huawei FusionServer Pro 2288H V5 Server Technical White Paper A Appendix Sensor Description Component PCIe$ NIC Temp PCIe card chip PCIe card temperature PS$ Inlet Temp PSU air inlet temperature NIC$ Presence LOM presence FlexIO N AEP Temp CPU DCPMM...
  • Page 101: B Glossary

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper B Glossary Glossary B.1 A-E baseboard The BMC complies with the Intelligent Platform management Management Interface (IPMI). It collects, processes, controller (BMC) and stores sensor signals, and monitors the operating status of components. The BMC provides the hardware...
  • Page 102: F-J

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper B Glossary B.2 F-J Gigabit Ethernet An extension and enhancement of traditional shared (GE) media Ethernet standards. It is compatible with 10M and 100M Ethernet and complies with IEEE 802.3z standards.
  • Page 103: U-Z

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper B Glossary redundancy A mechanism that allows a backup device to automatically take over services from a faulty device to ensure uninterrupted running of the system. redundant array of A storage technology that combines multiple physical...
  • Page 104: C Acronyms And Abbreviations

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System baseboard management controller...
  • Page 105: F-J

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper C Acronyms and Abbreviations direct current DDR3 double date rate 3 DDR4 double date rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module...
  • Page 106: K-O

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper C Acronyms and Abbreviations GPIO General Purpose Input/Output graphics processing unit high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller...
  • Page 107: P-T

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper C Acronyms and Abbreviations Lucent connector LRDIMM load-reduced dual in-line memory module light emitting diode LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface C.4 P-T...
  • Page 108 Huawei FusionServer Pro 2288H V5 Server Technical White Paper C Acronyms and Abbreviations RAID redundant array of independent disks reliability, availability and serviceability RDIMM registered dual in-line memory module REACH Registration Evaluation and Authorization of Chemicals RJ45 registered jack 45...
  • Page 109: U-Z

    Huawei FusionServer Pro 2288H V5 Server Technical White Paper C Acronyms and Abbreviations thermal design power TELNET Telecommunication Network Protocol Trusted Execution Technology TransFlash module TFTP Trivial File Transfer Protocol TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module...

Table of Contents