Huawei FusionServer Pro 2488H V6 Server
Technical White Paper
Issue
03
Date
2021-02-01
HUAWEI TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei FusionServer Pro 2488H V6

  • Page 1 Huawei FusionServer Pro 2488H V6 Server Technical White Paper Issue Date 2021-02-01 HUAWEI TECHNOLOGIES CO., LTD.
  • Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 3: About This Document

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper About This Document About This Document Purpose This document describes the 2488H V6 rack server in terms of features, structure, specifications, and component hardware and software compatibility. Intended Audience This document is intended for: ●...
  • Page 4 Huawei FusionServer Pro 2488H V6 Server Technical White Paper About This Document Symbol Description Supplements the important information in the main text. NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. Change History...
  • Page 5: Table Of Contents

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper Contents Contents About This Document........................ ii 1 Overview............................1 2 Features............................. 2 3 Physical Structure........................6 4 Logical Structure........................8 5 Hardware Description......................9 5.1 Front Panel....................................9 5.1.1 Appearance.................................... 9 5.1.2 Indicators and Buttons..............................11 5.1.3 Ports.......................................
  • Page 6 Huawei FusionServer Pro 2488H V6 Server Technical White Paper Contents 5.5.1 Drive Configurations.................................40 5.5.2 Drive Numbering................................49 5.5.3 Drive Indicators.................................. 54 5.5.4 RAID Controller Card................................ 56 5.6 Network....................................56 5.6.1 OCP 3.0 Network Adapter.............................. 56 5.7 I/O Expansion..................................56 5.7.1 PCIe Cards.................................... 57 5.7.2 PCIe Slots....................................
  • Page 7 Huawei FusionServer Pro 2488H V6 Server Technical White Paper Contents C Acronyms and Abbreviations................... 102 C.1 A-E......................................102 C.2 F-J......................................103 C.3 K-O......................................104 C.4 P-T......................................105 C.5 U-Z......................................107 Issue 03 (2021-02-01) Copyright © Huawei Technologies Co., Ltd.
  • Page 8: Overview

    Technical White Paper 1 Overview Overview Huawei FusionServer Pro 2488H V6 (2488H V6) is a new-generation 2U 4-socket rack server designed for Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom applications. The 2488H V6 is ideal for applications such as databases, cloud computing, virtualization, in-memory computing, and deep learning.
  • Page 9: Features

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 2 Features Features Performance and Scalability ® ® ● Powered by the third-generation Intel Xeon Scalable Cooper Lake processors, the server provides up to 28 physical cores, 3.9 GHz frequency, a 38.5 MB L3 cache, and six 10.4 GT/s UPI links between the processors, which...
  • Page 10 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 2 Features ® ● The server supports a maximum of 24 Intel Optane Persistent Memory Module 200 series (PMem modules for short). When the DDR4 memory modules are used together, the server supports a maximum of 18 TB memory capacity (calculated based on a maximum of 256 GB capacity per DDR4 memory module and a maximum of 512 GB capacity per PMem module).
  • Page 11 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 2 Features ● A password is required for accessing the BIOS, ensuring system boot and management security. ● The NC-SI feature allows a network port to serve as a management port and a service port.
  • Page 12 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 2 Features ● The server is protected with power capping and power control measures. ● Staggered spin-up of drives reduces the server boot power consumption. ● Intel Intelligent Power Capability allows the processor logic unit to be powered on or off based on requirements.
  • Page 13: Physical Structure

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 3 Physical Structure Physical Structure Figure 3-1 Physical structure of a 2488H V6 with 8 x 2.5" drives (example) PCIe riser module 1 PCIe cards PCIe riser module 2 PSUs Issue 03 (2021-02-01)
  • Page 14 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 3 Physical Structure PSU backplane Chassis Intrusion sensor Supercapacitor Primary air duct Secondary air ducts Drive backplane Fan module bracket Fan modules Drives Processors Processor heat sinks Cable organizers M.2 SSD Mainboard OCP 3.0 network adapter...
  • Page 15: Logical Structure

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 2488H V6 logical structure ® ® ● The server supports two or four third-generation Intel Xeon Scalable processors. ● The server supports up to 48 memory modules.
  • Page 16: Hardware Description

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Hardware Description 5.1 Front Panel 5.2 Rear Panel 5.3 Processor 5.4 Memory 5.5 Storage 5.6 Network 5.7 I/O Expansion 5.8 PSUs 5.9 Fan Modules 5.10 LCD 5.11 Boards 5.1 Front Panel...
  • Page 17 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description SAS/SATA drives (Optional) Built-in DVD drive (or LCD module) Slide-out label plate (with an SN label) ● 12 x 2.5" drive pass-through configuration (4 x SAS/SATA + 8 x NVMe)
  • Page 18: Indicators And Buttons

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-4 Front view SAS/SATA drives Filler panel in drive slot NOTE The slot cannot hold drives. Slide-out label plate (with an SN label) ● 25 x 2.5" drive EXP configuration (25 x SAS/SATA)
  • Page 19 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Fault diagnosis LED Power button/indicator Health status indicator UID button/indicator FlexIO card presence iBMC direct connect indicator management port indicator ● 12 x 2.5" drive pass-through configuration (4 x SAS/SATA + 8 x NVMe)
  • Page 20 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-9 Indicators and buttons on the front panel Fault diagnosis LED Power button/indicator Health status indicator UID button/indicator FlexIO card presence iBMC direct connect indicator management port indicator ●...
  • Page 21 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator/ Description Button Power Power indicator: button/ ● Off: The device is not powered on. indicator ● Steady green: The device is powered on. ● Blinking yellow: The iBMC is starting. The power button is locked and cannot be pressed.
  • Page 22: Ports

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator/ Description Button FlexIO card ● Off: The FlexIO card is not detected. presence ● Blinking green at 0.5 Hz: The FlexIO card is indicator detected but is not powered on.
  • Page 23 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description USB 3.0 ports iBMC direct connect management port VGA port ● 20 x 2.5" drive pass-through configuration (4 x SAS/SATA + 16 x NVMe) Figure 5-13 Ports on the front panel USB 3.0 ports...
  • Page 24: Rear Panel

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description USB 3.0 ports iBMC direct connect management port VGA port Port Description Table 5-2 Ports on the front panel Port Type Quantity Description VGA port DB15 Used to connect a display terminal, such as a monitor or KVM.
  • Page 25: Appearance

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description 5.2.1 Appearance Figure 5-16 Rear view PCIe slot 1 PCIe slot 2 PCIe slot 3 PCIe riser module 1 PCIe slot 4 PCIe slot 5 PCIe slot 6...
  • Page 26 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description FlexIO card status FlexIO card power indicator indicator Data transmission status Connection status indicator for the indicator for the management network management network port port Serial port indicators...
  • Page 27 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Silkscreen Indicator Description UID indicator The UID indicator helps identify and locate a device. ● Off: The device is not being located. ● Blinking or steady blue: The device is being located.
  • Page 28: Ports

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description FlexIO Card FlexIO Card Description Power Indicator Status Indicator (Green) (Yellow) Blinking at 0.5 Hz The FlexIO card has completed the hot swap process and is removable. Steady on The FlexIO card is faulty.
  • Page 29: Processor

    If two processors are required, install them in sockets CPU1 and CPU2. ● Processors of the same model must be used in a server. ● Contact your local Huawei sales representative or see "Search Parts" in the Computing Product Compatibility Checker to determine the components to be used.
  • Page 30: Memory

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-19 Processor positions 5.4 Memory 5.4.1 DDR4 Memory 5.4.1.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module.
  • Page 31: Memory Subsystem Architecture

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Callout Description Example Capacity ● 16 GB ● 32 GB ● 64 GB ● 128 GB Number of ranks ● 1R: single-rank ● 2R: dual-rank ● 4R: quad-rank Data width on the DRAM ●...
  • Page 32 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot DIMM031(J) E (primary) DIMM040(E) DIMM041(K) F (primary) DIMM050(F) DIMM051(L) CPU 2 A (primary) DIMM100(A) DIMM101(G) B (primary) DIMM110(B) DIMM111(H) C (primary) DIMM120(C) DIMM121(I) D (primary)
  • Page 33: Memory Compatibility

    ● The DDR4 memory modules of different types (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together. ● Contact your local Huawei sales representative or see "Search Parts" in the Computing Product Compatibility Checker to determine the components to be used.
  • Page 34 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description NO TICE The total memory capacity cannot exceed the maximum memory capacity supported by the CPUs. ● For details about the capacity type of a single memory module, see "Search Parts"...
  • Page 35: Memory Installation Guidelines

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description 5.4.1.4 Memory Installation Guidelines Observe the following when configuring DDR4 DIMMs: ● Install DIMMs only when corresponding processors are installed. ● Do not install LRDIMMs and RDIMMs in the same server.
  • Page 36 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-21 Memory slots Issue 03 (2021-02-01) Copyright © Huawei Technologies Co., Ltd.
  • Page 37: Memory Protection Technologies

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-22 DDR4 memory installation guidelines (2 processors) Figure 5-23 DDR4 memory installation guidelines (4 processors) 5.4.1.6 Memory Protection Technologies The following memory protection technologies are supported: ●...
  • Page 38: Pmem

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description ● Post Package Repair (PPR) ● Write Data CRC Protection ● Adaptive Data Correction - Single Region (ADC-SR) ● Adaptive Double Device Data Correction - Multiple Region(ADDDC-MR, +1) 5.4.2 PMem...
  • Page 39 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description The PMem modules must be used with the DDR4 memory modules, and the DDR4 memory module can be installed only in the memory slot of the primary memory channel.
  • Page 40: Memory Compatibility

    ● The DCPMMs must be used with the DDR4 memory modules. For details, see Huawei FusionServer Pro PMem 200 User Guide . ● Contact your local Huawei sales representative or see "Search Parts" in the Computing Product Compatibility Checker to determine the components to be used.
  • Page 41: Memory Installation Guidelines

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description ® ® ● The memory must be used with the third-generation Intel Xeon Scalable Cooper Lake processors. The maximum memory capacity supported varies depending on the processor model: –...
  • Page 42: Memory Installation Positions

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description – The PMem modules used in a server must have the same part number (P/N code). – The DDR4 DIMMs used with the PMem modules in a server must have the same part number (P/N code).
  • Page 43 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-25 Memory slots Issue 03 (2021-02-01) Copyright © Huawei Technologies Co., Ltd.
  • Page 44 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-26 PMem installation guidelines (2 processor) Issue 03 (2021-02-01) Copyright © Huawei Technologies Co., Ltd.
  • Page 45: Memory Protection Technologies

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-27 PMem installation guidelines (4 processor) 5.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ● PMem module Error Detection and Correction ● PMem module Device Failure Recovery (SDDC) ●...
  • Page 46: Storage

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description ● PMem module Viral ● PMem module Address Range Scrub (ARS) ● PMem module Error Injection ● DDR-T Command and Address Parity Check and Retry ● DDR-T Read Write Data ECC Check and Retry ●...
  • Page 47: Drive Configurations

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description 5.5.1 Drive Configurations Table 5-11 Drive configurations Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode 8 x 2.5" drive ● 8 x 2.5" ● 2 x M.2 ●...
  • Page 48 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode – 1 x PCIe RAID controll er card Manage s the M. 2 SSDs on the Avago SAS300...
  • Page 49 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode 12 x 2.5" ● 12 x 2.5" ● 2 x M.2 ● SAS/SATA drive pass- SSDs drive: – Slots 0...
  • Page 50 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode 20 x 2.5" ● 20 x 2.5" ● 2 x M.2 ● SAS/SATA drive pass- SSDs drive: – Slots 0...
  • Page 51 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode er card in slot Issue 03 (2021-02-01) Copyright © Huawei Technologies Co., Ltd.
  • Page 52 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode 24 x 2.5" ● 24 x 2.5" ● 2 x M.2 ● 2 x M.2 ● SAS/SATA drive pass-...
  • Page 53 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode slot ages drive s in slots 16 to ● M.2 SSD: – PCH Manage s the M. 2 SSDs on the M.2 SSD...
  • Page 54 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode controll er card in slot Issue 03 (2021-02-01) Copyright © Huawei Technologies Co., Ltd.
  • Page 55 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Configuratio Front Drive Rear Drive Built-in Drive Drive Management Mode 25 x 2.5" ● 25 x 2.5" ● 2 x M.2 ● 2 x M.2 ● SAS/SATA drive EXP...
  • Page 56: Drive Numbering

    4iMR PCIe RAID controll er card in slot Note: Contact your local Huawei sales representative or see "Search Parts" in Computing Product Compatibility Checker to determine the components to be used. 5.5.2 Drive Numbering NO TICE The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card.
  • Page 57 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Drive Number Drive Number Drive Number Displayed on the Identified by the RAID iBMC WebUI Controller Card ● 12 x 2.5" drive pass-through configuration (4 x SAS/SATA + 8 x NVMe)
  • Page 58 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description ● 20 x 2.5" drive pass-through configuration (4 x SAS/SATA + 16 x NVMe) Figure 5-30 Drive numbering Table 5-14 Drive numbering Drive Number Drive Number Drive Number...
  • Page 59 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-31 Drive numbering Table 5-15 Drive numbering Drive Number Drive Number Drive Number Displayed on the Identified by the RAID iBMC WebUI Controller Card Issue 03 (2021-02-01)
  • Page 60 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Drive Number Drive Number Drive Number Displayed on the Identified by the RAID iBMC WebUI Controller Card ● 25 x 2.5" drive EXP configuration (25 x SAS/SATA) Figure 5-32 Drive numbering...
  • Page 61: Drive Indicators

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Drive Number Drive Number Drive Number Displayed on the Identified by the RAID iBMC WebUI Controller Card 5.5.3 Drive Indicators SAS/SATA Drive Indicators Figure 5-33 SAS/SATA drive indicators...
  • Page 62 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description NVMe Drive Indicators Figure 5-34 NVMe drive indicators Table 5-18 NVMe drive indicators Activity Indicator Fault Indicator Description (Green) (Yellow) The NVMe drive is not detected. Steady on The NVMe drive is detected and operating properly.
  • Page 63: Raid Controller Card

    5.5.4 RAID Controller Card The RAID controller card supports RAID configuration, RAID level migration, and drive roaming. ● Contact your local Huawei sales representative or see "Search Parts" in the Computing Product Compatibility Checker to determine the components to be used.
  • Page 64: Pcie Cards

    A maximum of 11 PCIe 3.0 slots are supported, including one slot dedicated for the OCP 3.0 network adapter. ● Contact your local Huawei sales representative or see "Search Parts" in the Computing Product Compatibility Checker to determine the components to be used.
  • Page 65 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-37 PCIe riser module (universal 3-slot) ● PCIe riser module (universal 2-slot) – Provides PCIe slots 1 and 2 when installed in PCIe riser module 1. –...
  • Page 66: Pcie Slot Description

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-39 PCIe riser module (universal 3-slot, supporting GPUs) ● PCIe riser module (universal 2-slot, supporting GPUs) – Provides PCIe slots 1 and 2 when installed in PCIe riser module 1.
  • Page 67 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Table 5-20 PCIe slot description PCIe PCIe Conne Port Root Device Slot Slot Stand ctor Width Port (B/D/ Size ards Width (B/D/ FlexIO CPU 1 PCIe Port1A 0x15/0...
  • Page 68: Psus

    The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs with dual input live wires. ● Contact your local Huawei sales representative or see "Search Parts" in the Computing Product Compatibility Checker to determine the components to be used.
  • Page 69: Fan Modules

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-41 Positions of PSUs NO TE ● When one or two 900 W AC Titanium PSUs are configured and the input voltage ranges from 100 V AC to 127 V AC, the output power decreases to 550 W.
  • Page 70: Lcd

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-42 Positions of fan modules 5.10 LCD NO TE Only the 8 x 2.5" drive pass-through configuration (8 x SAS/SATA) supports the LCD. Function The LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management network port on the server.
  • Page 71: Boards

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Interface Figure 5-44 LCD main interface Table 5-21 Parameters on the LCD main interface Function Status Displays the port 80 status, serial number, component status, and component alarms of the server.
  • Page 72: Mainboard

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description 5.11.1 Mainboard Figure 5-45 2488H V6 mainboard Rear USB 3.0 port VGA port (VGA CONN/ (USB3.0*2/J80) J14) Serial port (IO/IO/J148) BMC management network port (BMC Mesg/ J149) PCIe slot 6 (PCIE...
  • Page 73 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description PCIe slot 4 (PCIE VROC key connector SLOT(CPU1) X8/J130) (SOFT RAID KEY/J1) NC-SI connector (NCSI PCIe riser 1 slot (PCIE CONN/J129) RISER1(CPU1)/J87) OCP 3.0 network adapter mini-SAS HD connector...
  • Page 74: Drive Backplane

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description LP slimline 2C connector Built-in USB 3.0 port (Slimline_2C/J65) (USB3.0/J75) 20-pin power connector Left mounting ear for the drive backplane connector (LEFT EAR (HDD BP POWER/J5) CONN/J9) Signal connector for the...
  • Page 75 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Indicator signal cable DVD drive power connector (REAR BP1/J3) connector (DVD/J11) Backplane signal cable Power connector connector (HDD BP/J1) (POWER/J2) mini-SAS HD Port A mini-SAS HD Port B...
  • Page 76 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description LP slimline 2 connector LP slimline 1 connector (Slimline2/J1201) (Slimline1/J1101) LP slimline 1D connector LP slimline 1C connector (Slimline_1D/J1801) (Slimline_1C/J1701) LP slimline 1A connector LP slimline 1B connector...
  • Page 77: Psu Backplane

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 5 Hardware Description Figure 5-50 25 x 2.5" drive EXP backplane (25 x SAS/SATA) Signal connector for the mini-SAS HD Port A rear backplane (REAR connector (PORTA/J28) BP0/J32) mini-SAS HD Port B...
  • Page 78: Product Specifications

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical specifications Category Specifications Form factor 2U rack server Chipset ® Intel...
  • Page 79 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Category Specifications Memory Supports 48 memory module slots. ● Up to 48 DDR4 memory modules – Max. 3200 MT/s memory speed – RDIMM and LRDIMM support – The DDR4 memory modules of different types...
  • Page 80 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Category Specifications Storage Supports a variety of drive configurations. For details, 5.5.1 Drive Configurations. ● Supports M.2 SSDs. – M.2 SSDs are supported for RAID configuration when the server is configured with an Avago SAS3004iMR RAID controller card.
  • Page 81 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Category Specifications NOTE If the BIOS is in legacy mode, the 4K drive cannot be used as the boot drive. Network Supports expansion capability of multiple types of networks.
  • Page 82: Environmental Specifications

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Category Specifications Video card An SM750 video with 32 MB display memory is integrated on the BMC chip (Hi1711). The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors.
  • Page 83 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Category Specifications Relative humidity (RH, ● Operating humidity: 8% to 90% non-condensing) ● Storage humidity (≤ 72 hours): 5% to 95% ● Storage humidity (> 72 hours): 30% to 69% ●...
  • Page 84: Physical Specifications

    – Cabinet width: 482.6 mm (19.00 in.) – Cabinet depth ≥ 1000 mm (39.37 in.) ● Requirements for guide rail installation: – L-shaped guide rails: apply only to Huawei cabinets. – Static rail kit: applies to cabinets with a distance of 543.5 mm to 848.5 mm (21.40 in.
  • Page 85 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 6 Product Specifications Category Description Weight in full ● Maximum net weight: configuration – Server with 8 x 2.5" drives: 28.19 kg (62.16 lb) – Server with 12 x 2.5" drives: 28.52 kg (62.89 lb) –...
  • Page 86: Software And Hardware Compatibility

    ● If the customer has requirements on the performance of specific application software, contact Huawei sales personnel to apply for POC tests in the pre-sales phase to determine detailed software and hardware configurations.
  • Page 87: Safety Instructions

    Take protective measures against radio interference before operating the device in residential areas. Personal Safety ● Only personnel certified or authorized by Huawei are allowed to install the hardware. ● Stop any operation that may cause personal injury or equipment damage, report the problem to a project supervisor immediately, and take protective measures.
  • Page 88 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 8 Safety Instructions Figure 8-1 Protective clothing ● Before touching a device, ensure that you are wearing ESD clothing and ESD gloves (or wrist strap), and remove any conductive objects (such as watches and jewelry).
  • Page 89 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ● Exercise caution when using tools that could cause personal injury. ● If the installation position of the device is above shoulder height, use a stacker to lift it.
  • Page 90: Maintenance And Warranty

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 8 Safety Instructions NO TE For details about the components supported by the server, see "Compatibility" in the Computing Product Compatibility Checker. ● Ensure that all devices are powered off before transportation.
  • Page 91: System Management

    Technical White Paper 9 System Management System Management The server uses Huawei proprietary intelligent Baseboard Management Controller (iBMC) to implement remote server management. The iBMC complies with IPMI 2.0 and provides highly reliable hardware monitoring and management. The iBMC supports the following features and protocols: ●...
  • Page 92 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 9 System Management – Multiple types of certificates can be imported and replaced to ensure data transmission security. ● System maintenance interface – The virtual KVM and virtual media functions facilitate remote maintenance.
  • Page 93: Certifications

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe Safety: EN 60950-1:2006+A11:2009+A1:2010+A12: 2011 EN 62368-1:2014+A11:2017 EMC: EN 55032:2012/AC:2013 CISPR 32:2012 EN 55032:2015/AC:2016 CISPR 32:2015 EN 55035:2017 CISPR 35:2016 ETSI EN 300 386 V1.6.1:2012...
  • Page 94 Huawei FusionServer Pro 2488H V6 Server Technical White Paper 10 Certifications Country/Region Certification Standards China RoHS SJ/T-11364 GB/T 26572 Australia AS/NZS CISPR32: 2015 EN 55032:2012/AC:2013 EN 55032:2015/AC:2016 America FCC Part 15 (Class A) America NRTL UL 62368-1:2014 Ed.2 C22.2#62368-1:2014 Ed.2] UL 60950-1:2007 Ed.2...
  • Page 95: A Appendix

    Table A-1 SN description Description SN ID (two characters), which is 21. Material identification code (eight characters), that is, processing code. Vendor code (two characters). 10 indicates Huawei, and other values indicate outsourcing vendors. Issue 03 (2021-02-01) Copyright © Huawei Technologies Co., Ltd.
  • Page 96: Operating Temperature Limitations

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Description Year and month (two characters). ● The first character indicates the year. – Digits 1 to 9 indicate years 2001 to 2009, respectively. – Letters A to H indicate years 2010 to 2017, respectively.
  • Page 97 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Configuration Max. 30°C (86°F) Max. 35°C (95°F) Max. 40°C (104°F) 12 x 2.5" drive ● All options Options Options pass-through supported: supported: supported configuration (4 x ● Processors of ●...
  • Page 98 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Configuration Max. 30°C (86°F) Max. 35°C (95°F) Max. 40°C (104°F) 24 x 2.5" drive Options Options ● Not supported pass-through supported: supported: configuration (24 ● Processors of ● Processors of...
  • Page 99: Nameplate

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Configuration Max. 30°C (86°F) Max. 35°C (95°F) Max. 40°C (104°F) ● a: When two full-length or four half-length GPU cards are configured, processors of up to 165 W are supported.
  • Page 100 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Sensor Description Component N Margin N Margin temperature N Prochot CPU Prochot N VDDQ Temp CPU VDDQ temperature CPU 1: components in positions U149 and U154 on the mainboard...
  • Page 101 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Sensor Description Component Power Server input power Total PSU power N indicates the PSU Power PSU input power PSU. number. The value is 1 or N Status N indicates the CPU CPU status CPU.
  • Page 102 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Sensor Description Component N indicates the DIMM DIMM status DIMM. DIMM slot number. PCH Status PCH chip fault diagnosis Component in position health status U240 on the mainboard LCD Presence...
  • Page 103 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Sensor Description Component SYS 12V_6 Mainboard 12.0 V voltage (the sixth output 12 V voltage detection for soft-start (riser 1 + slots 4/5/6)) SYS 12V_7 Mainboard 12.0 V voltage (the seventh...
  • Page 104 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Sensor Description Component N OP Temp OCP optical module temperature M2 Temp(PCIe Maximum temperature of all M.2 drives of the RAID controller card PCIe Status PCIe status PwrOn TimeOut...
  • Page 105 Huawei FusionServer Pro 2488H V6 Server Technical White Paper A Appendix Sensor Description Component NTP Sync Failed NTP synchronization failure and recovery events Host Loss System monitoring software (BMA) link loss detection N Temp GPU temperature N Inlet Temp PCIe...
  • Page 106: B Glossary

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper B Glossary Glossary B.1 A-E The baseboard management controller (BMC) complies with the Intelligent Platform Management Interface (IPMI). It collects, processes, and stores sensor signals, and monitors the operating status of components. The...
  • Page 107: F-J

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper B Glossary B.2 F-J Gigabit Ethernet An extension and enhancement of traditional shared (GE) media Ethernet standards. It is compatible with 10M and 100M Ethernet and complies with IEEE 802.3z standards.
  • Page 108: U-Z

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper B Glossary redundancy A mechanism that allows a backup device to automatically take over services from a faulty device to ensure uninterrupted running of the system. redundant array of A storage technology that combines multiple physical...
  • Page 109: C Acronyms And Abbreviations

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System baseboard management controller...
  • Page 110: F-J

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations direct current DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module DRAM dynamic random-access memory digital video disc...
  • Page 111: K-O

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations graphics processing unit high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller Industry Canada ICMP...
  • Page 112: P-T

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations Lucent Connector LRDIMM load-reduced dual in-line memory module light emitting diode LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface Open Compute Project C.4 P-T...
  • Page 113 Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations RAID redundant array of independent disks reliability, availability and serviceability RDIMM registered dual in-line memory module REACH Registration Evaluation and Authorization of Chemicals RJ45 registered jack 45...
  • Page 114: U-Z

    Huawei FusionServer Pro 2488H V6 Server Technical White Paper C Acronyms and Abbreviations thermal design power TELNET Telecommunication Network Protocol Trusted Execution Technology TransFlash module TFTP Trivial File Transfer Protocol TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module...

Table of Contents