Product Description
Additional PCB CZ-NS4P
Overview of the External Interfaces
Optional thermostat 2
L
N Cool Heat L
1
2
CN201
1
Swimming pool pump
2
3
Solar station
4
5
Fault reporting signal
6
1
Pump heatC. 1
2
3
Pump heatC. 2
CN205
4
Terminals
Connection
Function
CN201
Optional thermostat 2
Heating / cooling requirement of
1 to 4
thermostats.
L N = 230 V AC, Heat = heating,
CN202
Optional Thermostat 1
Cool = cooling
1 to 4
CN203
Mixing valve 1
230 V AC, N = Neutral, O = Open,
1 to 3
C = Closed = Direction reversal
Actuation duration: 30 to 120 s
CN203
Mixing valve 2
4 to 6
CN204
Temperature sensor
1 to 2
for swimming pool
PAW-A2W-TSHC
CN204
Infeed temperature
For measuring the water temperature in
3 to 4
sensor heatC. 2
the respective heating circuit
PAW-A2W-TSHC
CN204
Infeed temperature
5 to 6
sensor heatC. 1
PAW-A2W-TSHC
CN205
Room temperature
1 to 2
sensor heatC. 2
PAW-A2W-TSRT
CN205
Room temperature
3 to 4
sensor heatC. 1
PAW-A2W-TSRT
64
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Optional Thermostat 1
Mixing valve 1
Mixing valve 2
N Cool Heat
N
O
C
N
O
C
3
4
1
2
3
4
1
2
3
4
5
6
CN202
CN203
External compressor
1
switch
2
3
Heating/ Cooling Switch
4
1
Vcc
2
3
Bit1
SG-Signal
4
Bit2
CN204
CN207
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
Condition
Maximum total cable length: 50 m
Maximum total cable length: 50 m
Maximum total cable length: 30 m
Maximum total cable length: 30 m
Maximum total cable length: 30 m
Terminals
CN205
5 to 6
CN206
2 to 4
CN207
1 to 2
CN207
3 to 4
CN208
1 to 2
CN208
3 to 4
CN209
1 to 2
CN209
3 to 4
CN209
5 to 6
CN210
1 to 2
CN210
3 to 4
Connection conditions
The connection of the optional PCB allows temperature control for two heating circuits. Mixing
valves, circulation pumps and temperature sensors for heating circuits 1 and 2 are to be con-
Cable cross
section
nected to the corresponding terminals of the optional additional PCB. The temperatures in the
two heating circuits are controlled mutually independently by the operating unit.
4 × min.
0.5 mm²
Pumps for Heating Circuits 1 and 2:
● The cables of the pumps for heating circuits 1 and 2 must each be 2 x min.
3 × min.
1.5 mm²
● Maximum total cable length: 50 m
Solar station:
2 × min.
● The cable of the solar station must be 2 x min. 1.5 mm² and conform to the code
0.3 mm²
2 × min.
● Maximum total cable length: 50 m
0.3 mm²
Swimming pool pump:
● The cable of the swimming pool pump must be 2 x min. 1.5 mm² and conform to
● Maximum total cable length: 50 m
2 × min.
0.3 mm²
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Connection
Function
Temperature
For measuring the buffer tank
sensor for buffer tank
temperature
PAW-A2W-TSBU
SG-Signal
Smart Grid switch
Dry contact, Vcc-Bit1, Vcc-Bit2, Open /
Closed
Power control signal
0–10 V DC signal.
Solar temperature sen-
For measuring the solar module
sor PAW-A2W-TSSO
temperature
Pump heatC. 1
230 V AC, <500 W
Pump heatC. 2
Swimming pool pump
230 V AC
Solar station
230 V AC
Fault reporting signal
External compressor
Dry contact, Open = Outdoor unit ON,
switch
Closed = Outdoor unit OFF
Heating/ Cooling
Dry contact, Open = Heating, Closed =
Switch
Cooling
1.5 mm
2
and conform to the code 60245 IEC 57 or higher.
60245 IEC 57 or higher.
the code 60245 IEC 57 or higher.
Product Description
Condition
Cable cross
section
Maximum total cable length: 30 m
2 × min.
0.3 mm²
Must be connected to both contacts.
3 × min.
System setting needed.
0.3 mm²
Maximum total cable length: 50 m
Must be connected to 0-10 V DC control.
2 × min.
System setting needed.
0.3 mm²
Maximum total cable length: 50 m
Maximum total cable length: 30 m
2 × min.
0.3 mm²
Maximum total cable length: 50 m
2 × min.
1.5 mm²
Maximum total cable length: 50 m
2 × min.
1.5 mm²
Maximum total cable length: 50 m
2 × min.
1.5 mm²
System setting needed.
2 × min.
Maximum total cable length: 50 m
0.3 mm²
System setting needed.
2 × min.
Maximum total cable length: 50 m
0.3 mm²
65