SINAMICS S120 Fail-Safe Drives
Description
In order to accept the set-
tings that have been made,
click on "Copy parameters".
After the parameters have
been correctly accepted:
Click on the "Activate set-
tings" button.
(also in this case, change
the password when
commissioning the project
for the first time)
Click on "Axis parameters"
to save the changes in the
drive.
Acknowledge the following
message with "Yes".
The data is copied from the
RAM to ROM.
To save the actual project
status in the PG, carry-out
"Download to PG" and then
save the project.
Acknowledge any
messages regarding the
acceptance test;
also refer to Chapter 6.7
Acceptance test
Then carry-out a power-on
reset of the Control Unit.
Repeat this procedure for
the second drive!
I DT Safety Integrated
POWER ON
Refer to Chapter 6.6 Parameterizing the safety functions inte-
grated in the drive
Page 41/43