SINAMICS S120 Fail-Safe Drives
Description
To accept the settings that have
been made, click on "Copy parame-
ters".
Click on "Activate settings".
When commissioning the project for
the first time, you will be prompted to
change the safety password. The
default password when commission-
ing the project for the first time is "0"
The password can be up to 8 charac-
ters long and is saved in the hexa-
decimal format.
Acknowledge the message opposite
with "Yes".
Data is copied from RAM to ROM.
To save the current project status in
the PG, execute "Download to PG"
and then save the project.
Then, carry-out a power-on reset of
the Control Unit.
6.6

Parameterizing the safety functions integrated in the drive

Description
Before you start the actual
parameterization process:
Restart the system (new
start).
I DT Safety Integrated
POWER ON
POWER ON
Page 37/43