 Connection Management Object (06h)
This object is used to manage the characteristics of a communication connection.
 Service
Class
 Motor Data Object (28h)
This object serves as a database for motor parameters.
 Service
Class
Get_Attribute_Single
 Class attribute
No.
Name
1
Revision
 Instance attribute
No.
Name
3
MotorType
6
Rated Current
7
Rated Voltage
9
RatedFreq
12
PoleCount
15
Rated Speed
*1
Writing is enabled only when the setting is the same as that of the inverter.
*2
When Pr.81 (Pr.454) = "9999", the formula is calculated with 4 poles.
 Control Supervisor Object (29h)
This object has the management functions for devices "Hierarchy of Motor Control Devices".
 Service
Class
Get_Attribute_Single
 Class attribute
No.
Name
1
Revision
 Instance attribute
No.
Name
*1
3
Run1
*1
4
Run2
Instance
Forward_Open
Forward_Close
Instance
Get_Attribute_Single
Set_Attribute_Single
Access
Get
UINT
Access
*1
USINT
Set
Set
UINT
Set
UINT
Set
UINT
Set
UINT
Set
UINT
Instance
Get_Attribute_Single
Set_Attribute_Single
Reset (operation command clear,
output shutoff)
Access
Get
UINT
Access
Set
BOOL
Set
BOOL
Type
0001h (Revision of the object)
Type
3: PM synchronous motor
7: Squirrel cage induction motor
Rated motor current (0.1 A increments)
Instance 1: Pr.9
Instance 2: Pr.51
Rated motor voltage (V)
Instance 1: Pr.83
Instance 2: Pr.456
Rated motor frequency (Hz)
Instance 1: Pr.84
Instance 2: Pr.457
Number of motor poles
Instance 1: Pr.81
Instance 2: Pr.454
\Nominal speed (rpm) at rated frequency from nameplate
Instance 1: Pr.84 × 120/Pr.81
Instance 2: Pr.457 × 120/Pr.454
Type
0001h (Revision of the object)
Type
Forward rotation
Reverse rotation
Description
Description
Description
Description
2. Ethernet Communication
2.11 EtherNet/IP
1
2
3
4
5
6
7
8
9
10
*2
107

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800

Table of Contents