Chapter 1 Overview

1.4 Switch Settings

Each switch is set as follows.
( DIP switch is all OFF at the factory. )
4
Baud rate setting
Baud rate
300
SW-8
OFF
SW-7
OFF
SW-6
OFF
8
Baud rate
7
6
Stop bit (2bit/1bit)
5
Data bit length (7bits/8bits)
4
Parity bit (Non Parity/Parity)
3
Parity bit (Even/Odd)
2
No use
1
ON→
Notes
1. The transmission format can be the following combination.
Start bit
1
1
1
1
( In the combination except the above, it isn't possible to work. )
2. The switch setting status is recognized at module initialization by turning
power on, pressing the hardware reset switch or issuing the software
reset command (cold reset).
3. At the time of power ON, don't change a DIP switch.
4. The factory settings are all OFF. Set these switches are required before
using this module.
600
1200
OFF
OFF
OFF
ON
ON
OFF
SW-5:Stop bit
SW-4:Data bit length
SW-3:Parity (Parity / Non parity)
SW-2:Parity (Odd / Even)
Data
bit
Parity
length
7
available
7
available
8
Non
8
available
2400
4800
9600
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
1 stop bit
OFF
2 stop bit
ON
8 bit
OFF
7 bit
ON
Parity
OFF
Non Parity
ON
Odd parity
OFF
Even parity
Stop bit
1
2
1
1
model 2000 CIF Module (CF611) User's Manual
19200
ON
ON
OFF