4
Names of Part and Details of Mounting Portion
Exhaust fan
Air intake area
(Opposit side
is identical)
F.G.
connection screw
M4 depth 5.5
UV emitting window
When installed, please fix the parts firmly, use the eight M4 screws of on both sides.
(Standard of tightening torque : 1.0N·m)
Connection (Wiring)
5
Connector Pin Arrangement
Connector-1
NJW-2824-PF16
Pin No.
Content
Block
1
LED 365nm
2
COM
3
LED 385nm
4
5
6
7
8
9
10
1
Anode(+)
11
1
Cathode(-)
12
2
Anode(+)
13
2
Cathode(-)
14
3
Anode(+)
15
3
Cathode(-)
16
1
FAN(+)
17
18
1
FAN(-)
19
2
FAN(+)
20
21
2
FAN(-)
22
3
FAN(+)
23
24
3
FAN(-)
Details of the connector pin number #1 - #3
These signals from the external device is used for detecting wavelength of LED and
the cable is connected correctly.
In Connector-1 : Connected as follows inside the LED head at LED Wavelength
If LED wavelength is 365nm, pin #1 - #2 is shorted and pin #3 is opened.
If LED wavelength is 385nm, pin #2 - #3 is shorted and pin #1 is opened.
In Connector-2 : #1, #2 and #3 is shorted.
Details of the connector pin number #10 - #15
These pins connect the constant current DC power supply for lighting the LED.
Prepare the power supplies of the following specifications for the number of blocks to
be connected.
Type of power source :Constant current DC power supply
Open voltage
:DC40V (Min)
Max current
:3A
The current flowing through the LED, please use less than the current value, which is
defined by specifications or the like.
Please do not mistake the polarity of the power supply to be connected.
If have a current greater than that specified, if make a mistake the polarity of the
power supply, there is a risk of damage to the LED.
Cable
4×M4 depth 5.5
(Opposit side
Connector
is identical)
Mounting screws
(Opposit side
is identical)
Details of mounting portion
Connector-2
NJW-2824-PFX16
Pin No.
Content
Block
1
LED Connect Check 1
2
COM
3
LED Connect Check 2
4
5
6
7
8
9
10
4
Anode(+)
11
4
Cathode(-)
12
5
Anode(+)
13
5
Cathode(-)
14
6
Anode(+)
15
6
Cathode(-)
16
4
FAN(+)
17
18
4
FAN(-)
19
5
FAN(+)
20
21
5
FAN(-)
22
6
FAN(+)
23
24
6
FAN(-)
Note) Please do not connect on blank terminal.
Details of the connector pin number #16 - #24
These pins connect the constant voltage DC power supply for fan.
Prepare the power supplies of the following specifications for the number of blocks
to be connected.
Type of power source : Constant voltage DC power supply
Output voltage
Max current
Prepare the power supply of the following specifications when controlling the fan all
at once.
Method of wiring
Type of power source : Constant voltage DC power supply
10
30
Output voltage
Max current
If turn on the LED, please be sure to operate the fan.
Please do not mistake the polarity of the power supply to be connected.
If you enter the wrong polarity, the fan does not operate.
There is a possibility that the fan fails.
Lighting up the LED without operating the fan may damage the LED.
Cable to be soldered to connector
Cable cross-sectional area
Resistance temperature
Voltage endurance
Diameter of the entire wiring
              (Inner diameter of connector grommet : 16mmφ)
Length
Make sure to solder it properly.
  See the official website or the catalog of "NANABOSHI ELECTRIC MFG CO., LTD." for
  details on soldering onto the connector and its handling.
Wire the connection cable without extra load being applied.
Connection or disconnection, please perform in the state that power turned off.
Specifications
6
Model name
Number of blocks
Power consumption (Maximum)
Light source
Peak irradiation
intensity
※1
Effective irradiation
width
※1
Predicted life
※1
Temperature detection of LED
Operating ambient temperature
Operating ambient humidity
Storage ambient temperature
Storage ambient humidity
Cooling system
Size
Weight
(Without connector and cable)
Outer surface finish
Standard
Included Items
(Connector for wiring)
※1 It depends on our standard of measurement.
It is a representative value and is not a guarantee value.
※2 WD: Working Distance, Irradiation distance (Unit : mm)
※3 Connector made by "NANABOSHI ELECTRIC MFG CO., LTD."
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
PRINTED IN JAPAN
(General switching power supply can be used.)
:DC12V±5%
:1A
: Parallel connection of FAN(+) and FAN(-)
(General switching power supply can be used.)
:DC12V±5%
:(1×number of blocks) A
: Larger than 0.5mm
: More than 100℃
: More than 100V
: Less than 16mmφ at per connector
: Within 5m (Between head and power supply)
λ:365nm
ANUD4A111 ANUD4A211 ANUD4A311 ANUD4A411 ANUD4A511 ANUD4A611
λ:385nm
ANUD4B111 ANUD4B211 ANUD4B311 ANUD4B411 ANUD4B511 ANUD4B611
1
2
3
100W
200W
300W
365nm±10nm / 385nm±10nm
2
WD10mm
※2
4,200mW/cm
(at 365nm) / 4,600mW/cm
2
WD30mm
※2
2,300mW/cm
(at 365nm) / 2,600mW/cm
WD10mm
※2
36mm
108mm
180mm
WD30mm
※2
16mm
88mm
160mm
15,000 hours (70% of initial UV intensity)
Thermistor deployment
0 to +35℃
30 to 85% RH (Without dew condensation and freezing)
-10 to +60℃
30 to 85% RH (Without dew condensation and freezing)
Forced air cooling by fan
Width
50mm
Length
159mm
231mm
303mm
Height
142mm (Including receptacle, without connector and cable)
1.3kg
1.8kg
2.3kg
Cover part : A5052 (Black alumite finish)
JIS C7550 / IEC 62471
NJW-2824-PF16
※3
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
2
(AWG23)
4
5
6
400W
500W
600W
2
(at 385nm)
2
(at 385nm)
252mm
324mm
396mm
232mm
304mm
376mm
405mm
477mm
549mm
3.0kg
3.5kg
4.0kg
NJW-2824-PF16
NJW-2824-PFX16
8A3 L23 7000 1