Leakage testing

Pressure: 0.08 MPa (0.8 kgf/cm
Max. leakage: 0.02 MPa per 30 see
(0.2 kgf/cm2 per 30 sec. )
Tools: 502 50 38-01 Pressure tester
502 50 45-01 Spacer sleeve (35 mm)
502 50 47-01 Sealing plate, inlet
502 50 48-01 Sealing plate, exhaust
Starter
It should be possible to turn the cord pulley about
another half-turn when the starter cord 15 fully with-
drawn.
Carburettor
Pressure: 0.03 MPa (0.3kgf/cm
Leakage: No leakage permitted
Tools: 502 50 38-01 Pressure tester
502 50 45-01 Spacer sleeve (35 mm)
502 50 47-01 Sealing plate, inlet
502 50 48-01 Sealing plate, exhaust
2
)
2
, 4.3 psi)
2:1