5.1. Function test

BEKOMAT
8/9
®
Testing normal function
To test the solenoid valve, press the test button briefly (for approx. 2 seconds).
 Red "ALARM" LED flashes, yellow "VALVE" led is lit
 Valve to condensate discharge is opened
Testing alarm function
To test the solenoid valve alarm function, close the condensate inlet and press and
hold the test button for approx. 1 minute.
 Alarm relay switches over
Release TEST button
 BEKOMAT
returns to normal mode operation
®
Condensate inlet is again open!
Min. operating pressure 0.5 bar!