SIMATIC RTLS4030G
SIMATIC RTLS
Localization systems
SIMATIC RTLS4030G
Operating Instructions
06/2020
C79000-G8976-C515-03
Introduction
Device description
Installation & Operation
Technical specifications
Approvals
1
2
3
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RTLS Series

  • Page 1 SIMATIC RTLS4030G Introduction Device description Installation & Operation SIMATIC RTLS Technical specifications Localization systems SIMATIC RTLS4030G Approvals Operating Instructions 06/2020 C79000-G8976-C515-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................. 5 Device description ........................... 9 Characteristics .......................... 9 Order data RTLS4030G ......................10 Pin assignment ........................11 LED status indicator ........................ 12 Dimension drawing ......................... 13 Troubleshooting ........................13 Installation & Operation ......................... 15 Notes on installation........................ 15 Mounting for ceiling mount ......................
  • Page 4 Table of contents SIMATIC RTLS4030G Operating Instructions, 06/2020, C79000-G8976-C515-03...
  • Page 5: Introduction

    Industrial Ethernet network. You can find the system manual at the following link: (https://support.industry.siemens.com/cs/us/en/ps/25277) Trademarks The following and possibly other names not identified by the registered trademark sign ® registered trademarks of Siemens AG: SIMATIC RTLS SIMATIC RTLS4030G Operating Instructions, 06/2020, C79000-G8976-C515-03...
  • Page 6 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
  • Page 7 Introduction To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under: (https://support.industry.siemens.com/cs/us/en/ps/15247/pm) Recycling and disposal The products are low in harmful substances, can be recycled and meet the requirements of the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE).
  • Page 8 Introduction SIMATIC RTLS4030G Operating Instructions, 06/2020, C79000-G8976-C515-03...
  • Page 9: Device Description

    Device description Characteristics SIMATIC RTLS4030G Characteristics ① Design Status indicators (LEDs) ② Connector for power supply over mains connection ③ Ethernet port; Alternative power supply using Power over Ethernet (PoE) General The device is the home location for localiza- tion in the RTLS localization system. It can be connected to the local IT infrastruc- ture over Ethernet.
  • Page 10: Order Data Rtls4030G

    Device description 2.2 Order data RTLS4030G Order data RTLS4030G Table 2- 1 Order data RTLS4030G Article number SIMATIC RTLS4030G 6GT2701-5DB03 FCC/NOM 6GT2701-5DB13 CMIIT 6GT2701-5DB23 Table 2- 2 Accessories order data (not included in scope of delivery) Article number Connecting cable for gateway 6GT2791-2AH50 Bulgin 400 Series Buccaneer®...
  • Page 11: Pin Assignment

    Device description 2.3 Pin assignment Pin assignment Ethernet socket RJ45 The device may only be connected to the Ethernet via the plug-in connectors shown below. When connecting the Ethernet cable, ensure that the twist-lock connectors are correctly secured. Connections ● 3-pin plug-in connector Buccaneer® PX0412/03P ●...
  • Page 12: Led Status Indicator

    Device description 2.4 LED status indicator Figure 2-1 RJ45 connector Amphenol LTW PCP-00AMMA-TLM7001 LED status indicator The operating states of the gateways are indicated by the LEDs. The states can be off , on and flashing Meaning POWER LED Lights up green when power is supplied to the device through the mains cable RADIO LED Off when the radio signal of the device to other gateways or transponders is inactive RADIO LED...
  • Page 13: Dimension Drawing

    Device description 2.5 Dimension drawing Dimension drawing Figure 2-2 Dimension drawing SIMATIC RTLS4030G - All dimensions specified in millimeters Troubleshooting Error detection Cause of the error Troubleshooting Device does not respond, all LEDs are off The device is not connected or the Check the supply voltage of the device.
  • Page 14 Device description 2.6 Troubleshooting SIMATIC RTLS4030G Operating Instructions, 06/2020, C79000-G8976-C515-03...
  • Page 15: Installation & Operation

    Make sure that the wiring is correct before you start up the device. Only use the cables described in the order data, supplied with the device or otherwise prescribed. Siemens AG is not liable for damage or functional limitations caused by the use of other cables.
  • Page 16 Installation & Operation 3.1 Notes on installation Supply voltage When the supply voltage is connected to the power plug, all LEDs flash briefly for a moment. The POWER LED lights up as soon as voltage is present. You can supply the device with power via the Ethernet cable. In this case, the power plug must be tightly sealed to prevent moisture from penetrating.
  • Page 17 Installation & Operation 3.1 Notes on installation Installation without holder Do the following to mount the device without holder to the wall: 1. Draw the bore holes on the wall according to the following drilling pattern. 2. Drill the holes with a suitable device. 3.
  • Page 18: Mounting For Ceiling Mount

    Installation & Operation 3.2 Mounting for ceiling mount Mounting for ceiling mount Follow the steps below to mount the device to the wall/ceiling: 1. Use the mounting plate as template and draw the bore holes on the ceiling. 2. Drill the holes with a suitable device. 3.
  • Page 19: Mounting For Corner And Pole Mount

    Installation & Operation 3.3 Mounting for corner and pole mount Mounting for corner and pole mount Follow the steps below to mount the device to a corner/mast: 1. Use the universal support as template and draw the bore holes on the corner / mast. 2.
  • Page 20: Operation

    Unauthorized opening of and improper repairs to the device may cause substantial risks to the user. As soon as the device was opened without permission, warranty and liability of the Siemens AG are rendered null and void. Do not clean the enclosure with abrasive, alkaline or aggressive cleaning products or aids.
  • Page 21: Technical Specifications

    Technical specifications Table 4- 1 Technical specifications of the gateway RTLS4030G 6GT2701-5DB03, 6GT2701-5DB13 6GT2701-5DB23 Product name SIMATIC RTLS4030G PULSE radio frequencies Wireless method IEEE 802.15.4-2015 UWB HRP PHY Transmission speed 850 kbit/s Operating frequency rated value 3993.6 MHz (UWB channel 2; CE, FCC/NOM) 6489.6 MHz (UWB channel 5;...
  • Page 22 Technical specifications 6GT2701-5DB03, 6GT2701-5DB13 6GT2701-5DB23 Supply voltage, power consumption Supply voltage DC 8 ... 30 V Rated voltage DC 24 V Power consumption Current consumption 0.38 A Permitted ambient conditions Ambient temperature During operation -15 ... +50 °C • • During storage -15 ...
  • Page 23: Approvals

    Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.com/cs/products?dtp=Certificate&mfn=ps&pnid=14970&lc= en-US) The products described in this document meet the requirements of the following EU directives: ● RoHS Directive 2011/65/EU...
  • Page 24 Approvals Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems ●...
  • Page 25 The specified approvals are only valid if the corresponding symbol is printed on the device. FCC information Siemens SIMATIC RTLS4030G (MLFB 6GT2701-5DB13); FCC ID SCF6032502 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:...
  • Page 26 Approvals NOM información Siemens SIMATIC RTLS4030G (MLFB 6GT2701-5DB13); IFT RCPSIRT19-1570 La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no...

This manual is also suitable for:

Simatic rtls4030g

Table of Contents