SIMATIC RTLS
Localization systems
SIMATIC RTLS PCB OEM AC
Operating Instructions
02/2023
C79000-G8976-C519-06
Introduction
Device description
Installation & Operation
Technical specifications
Approvals
1
2
3
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RTLS

  • Page 1 SIMATIC RTLS PCB OEM AC Introduction Device description SIMATIC RTLS Installation & Operation Technical specifications Localization systems SIMATIC RTLS PCB OEM AC Approvals Operating Instructions 02/2023 C79000-G8976-C519-06...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Order data RTLS PCB OEM AC ..................... 10 Pin assignment ........................10 LED status indicator ......................10 Dimension drawing ......................11 Installation & Operation ........................13 Notes on installation ......................13 Technical specifications ........................15 Approvals ............................. 17 SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 4 Table of contents SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 5: Introduction

    • RTLS PCB OEM AC (FCC; article number: 6GT2700-8DF10-0AX1) Further documentation The system manual "Commissioning SIMATIC RTLS" provides information on other SIMATIC RTLS products that you can operate together with the devices in this product line in an Industrial Ethernet network.
  • Page 6 Introduction Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support offers support at the following Internet address: (https://support.industry.siemens.com/cs/start?lc=en-US) Apart from news, there you will also find: • Project information: Manuals, FAQs, downloads, application examples etc.
  • Page 7 Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats. To ensure that you are always informed about product updates, subscribe to the Siemens Industrial Security RSS feed at: (https://www.siemens.com/cert) Note on firmware/software support Check regularly for new firmware/software versions or security updates and apply them.
  • Page 8 Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations.
  • Page 9: Device Description

    Precautionary measures against electrostatic discharge The RTLS transponder can be damaged by electrostatic discharge (ESD). Take suitable precautionary measures when unpacking and operating the transponder to avoid damage. Characteristics SIMATIC RTLS PCB OEM AC Characteristics Setup ① Status indicators (LED) ②...
  • Page 10: Order Data Rtls Pcb Oem Ac

    Device description 2.3 Order data RTLS PCB OEM AC Order data RTLS PCB OEM AC Table 2- 1 Order data RTLS PCB OEM AC Article number SIMATIC RTLS PCB OEM AC 6GT2700-8DF00-0AX1 6GT2700-8DF10-0AX1 Pin assignment P2 socket Type: JST SM02B-SRSS-TB Description / Function Supply voltage, 3.3 V DC...
  • Page 11: Dimension Drawing

    Dimension drawing The UWB antenna is arranged diagonally standing up on the top side of the PCB. Figure 2-1 Dimension drawing SIMATIC RTLS PCB OEM AC - All dimensions specified in millimeters SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 12 Device description 2.6 Dimension drawing SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 13: Installation & Operation

    The label is required to identify the device with the installed transponder in the Locating Manager. Maintenance Only authorized dealers or the manufacturer are permitted to repair the device. SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 14 Installation & Operation 3.1 Notes on installation SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 15: Technical Specifications

    Technical specifications Table 4- 1 Technical specifications of the transponder RTLS PCB OEM AC 6GT2700-8DF00-0AX1, 6GT2700-8DF10-0AX1 Product name SIMATIC RTLS PCB OEM AC PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2015 UWB HRP PHY Transmission speed 850 kbit/s Operating frequency rated value 3993.6 MHz (UWB channel 2;...
  • Page 16 Dimensions of board (L x W x H) 25 x 25 x 18 mm Dimensions of antenna (L x W x H) 20.6 x 12.7 x 1.6 mm Weight Degree of protection IP00 Fastening method Provided by customer SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 17: Approvals

    The UK declaration of conformity is available to all responsible authorities at: Siemens Aktiengesellschaft Process Industries and Drives Division, Process Automation DE-76181 Karlsruhe Germany Importer UK: Siemens plc, Manchester M20 2UR SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 18 You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/en/en/view/109801531). The SIMATIC RTLS products described in this document meet the requirements of the following directives/regulation: • Radio Equipment Regulations: SI 2017/1206 Radio Equipment Regulations 2017, and related amendments •...
  • Page 19 • ETSI EN 302 065-2 Short Range Devices (SRD) using ultra-wideband technology (UWB); Harmonized standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 2: Requirements for UWB location tracking SIMATIC RTLS PCB OEM AC Operating Instructions, 02/2023, C79000-G8976-C519-06...
  • Page 20 Approvals FCC information Siemens SIMATIC RTLS PCB OEM AC (6GT2700-8DF10-0AX1); Contains FCC ID NXWOEMAC This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Table of Contents